Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients

被引:60
作者
Iotti, GA
Olivei, MC
Palo, A
Galbusera, C
Veronesi, R
Comelli, A
Brunner, JX
Braschi, A
机构
[1] POLICLIN SAN MATTEO, IRCCS, LAB BIOTECNOL & TECNOL BIOMED, I-27100 PAVIA, ITALY
[2] HAMILTON BONADUZ AG, BONADUZ, SWITZERLAND
关键词
respiration; artificial instrumentation; heat and moisture exchanger; respiratory mechanics; pressure support ventilation; P-0.1; feedback control;
D O I
10.1007/s001340050347
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective:To investigate the mechanical effects of artificial noses. Setting: A general intensive care unit of a university hospital. Patients: 10 patients in pressure support ventilation for acute respiratory failure. Interventions: The following three conditions were randomly tested on each patient: the use of a heated humidifier (control condition), the use of a heat and moisture exchanger without filtering function (HME), and the use of a combined heat and moisture exchanger and mechanical filter (HMEF). The pressure support level was automatically adapted by means of a closed-loop control in order to obtain constancy, throughout the study, of patient inspiratory effort as evaluated from airway occlusion pressure at 0.1 s (P-0.1). Patient's ventilatory pattern, P-0.1, work of breathing, and blood gases were recorded. Measurements and main results: The artificial noses increased different components of the inspiratory load: inspiratory resistance, ventilation requirements (due to increased dead space ventilation), and dynamic intrinsic positive end-expiratory pressure (PEEP). The additional load imposed by the artificial noses was entirely undertaken by the ventilator, being the closed-loop control of P-0.1 effective to maintain constancy of patient inspiratory work by means of adequate increases in pressure support level. Conclusions: The artificial noses cause unfavorable mechanical effects by increasing inspiratory resistance, ventilation requirements, and dynamic intrinsic PEEP. Clinicians should consider these effects when setting mechanical ventilation and when assessing patients' ability to breathe spontaneously.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 33 条
[1]  
AGOSTONI E, 1964, HANDBOOK PHYSIOLOG 3, V1, P387
[2]   P0.1 IS A USEFUL PARAMETER IN SETTING THE LEVEL OF PRESSURE SUPPORT VENTILATION [J].
ALBERTI, A ;
GALLO, F ;
FONGARO, A ;
VALENTI, S ;
ROSSI, A .
INTENSIVE CARE MEDICINE, 1995, 21 (07) :547-553
[3]  
*AM HTOR SOC, 1987, AM J RESP CRIT CARE, V136, P225
[4]   INSPIRATORY MUSCLE DYSFUNCTION AND CHRONIC HYPERCAPNIA IN CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BEGIN, P ;
GRASSINO, A .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (05) :905-912
[5]   Mechanism of relief of tachypnea during pressure support ventilation [J].
Berger, KI ;
Sorkin, IB ;
Norman, RG ;
Rapoport, DM ;
Goldring, RM .
CHEST, 1996, 109 (05) :1320-1327
[6]   EFFECT OF 2 TIDAL VOLUMES ON OXYGENATION AND RESPIRATORY SYSTEM MECHANICS DURING THE EARLY-STAGE OF ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
BLANCH, L ;
FERNANDEZ, R ;
VALLES, J ;
SOLE, J ;
ROUSSOS, C ;
ARTIGAS, A .
JOURNAL OF CRITICAL CARE, 1994, 9 (03) :151-158
[7]   HUMIDIFICATION IN THE INTENSIVE-CARE UNIT - PROSPECTIVE-STUDY OF A NEW PROTOCOL UTILIZING HEATED HUMIDIFICATION AND A HYGROSCOPIC CONDENSER HUMIDIFIER [J].
BRANSON, RD ;
DAVIS, K ;
CAMPBELL, RS ;
JOHNSON, DJ ;
POREMBKA, DT .
CHEST, 1993, 104 (06) :1800-1805
[8]   IMPROVED EFFICACY OF SPONTANEOUS BREATHING WITH INSPIRATORY PRESSURE SUPPORT [J].
BROCHARD, L ;
PLUSKWA, F ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (02) :411-415
[9]  
BRUNNER JX, 1988, PULMONARY FUNCTION I, P18
[10]   USE OF HEAT AND MOISTURE EXCHANGING (HME) FILTERS IN MECHANICALLY VENTILATED ICU PATIENTS - INFLUENCE ON AIRWAY FLOW-RESISTANCE [J].
CHIARANDA, M ;
VERONA, L ;
PINAMONTI, O ;
DOMINIONI, L ;
MINOJA, G ;
CONTI, G .
INTENSIVE CARE MEDICINE, 1993, 19 (08) :462-466