Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples

被引:220
作者
Li, Shengqing [1 ,2 ]
Cai, Shun [1 ]
Hu, Wei [1 ]
Chen, Hao [1 ]
Liu, Hanlan [1 ]
机构
[1] Huazhong Agr Univ, Coll Sci, Dept Chem, Wuhan 430070, Peoples R China
[2] Minist Agr, Supervis Inspect & Testing Ctr Microbial Prod Qua, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
Room temperature ionic liquids; Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction; Electrothermal atomic absorption spectrometry; Cadmium; PLASMA-MASS SPECTROMETRY; PHASE EXTRACTION SPE; ORGANOPHOSPHORUS PESTICIDES; MICRO-EXTRACTION; ARRAY DETECTION; PRECONCENTRATION; SEPARATION; MERCURY;
D O I
10.1016/j.sab.2009.05.023
中图分类号
O433 [光谱学];
学科分类号
070207 [光学];
摘要
A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF6), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium-DDTC complex was formed and extracted into the fine droplets of HMIMPF6. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent. the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 mu L of HMIMPF6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L-1, and the characteristic mass (m(0), 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L-1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2-106%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:666 / 671
页数:6
相关论文
共 38 条
[1]
Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters [J].
Aguilera-Herrador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) :106-111
[2]
Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[3]
Development of on-line single-drop micro-extraction sequential injection system for electrothermal atomic absorption spectrometric determination of trace metals [J].
Anthemidis, Aristidis N. ;
Adam, Ibrahim S. I. .
ANALYTICA CHIMICA ACTA, 2009, 632 (02) :216-220
[4]
Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids [J].
Baghdadi, Majid ;
Shemirani, Farzaneh .
ANALYTICA CHIMICA ACTA, 2008, 613 (01) :56-63
[5]
Comparison of liquid-liquid extraction (LLE), solid-phase extraction (SPE), and solid-phase microextraction (SPME) for pyrethroid pesticides analysis from enriched river water [J].
Barrionuevo, WR ;
Lanças, FM .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2002, 69 (01) :123-128
[6]
Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[7]
Monitoring of selenium. in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry [J].
Bidari, Araz ;
Jahromi, Elham Zeini ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani .
MICROCHEMICAL JOURNAL, 2007, 87 (01) :6-12
[8]
Advances in electrothermal atomization atomic absorption spectrometry: Instrumentation, methods, and applications [J].
Butcher, DJ .
APPLIED SPECTROSCOPY REVIEWS, 2006, 41 (01) :15-34
[9]
Ultrasound in analytical chemistry [J].
Capote, F. Priego ;
Luque de Castro, M. D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :249-257
[10]
Determination of cadmium in biological samples [J].
Davis, AC ;
Wu, P ;
Zhang, XF ;
Hou, XD ;
Jones, BT .
APPLIED SPECTROSCOPY REVIEWS, 2006, 41 (01) :35-75