Wrist joint motion simulator

被引:84
作者
Werner, FW [1 ]
Palmer, AK [1 ]
Somerset, JH [1 ]
Tong, JJ [1 ]
Gillison, DB [1 ]
Fortino, MD [1 ]
Short, WH [1 ]
机构
[1] SYRACUSE UNIV,DEPT MECH & AEROSP ENGN,SYRACUSE,NY 13244
关键词
D O I
10.1002/jor.1100140420
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A computer controlled wrist joint motion simulator has been developed that actively moves forearms from cadavers through cyclic planar flexion-extension motions, planar radial-ulnar deviation motions, and combined motions such as circumduction, Hybrid position-force feedback control algorithms are used to determine the wrist flexor and extensor tendon forces necessary to achieve the desired motions. The simulator was used in a series of 12 fresh cadaver forearms to produce both flexion-extension and radial-ulnar deviation motions and was found to cause repeatable, physiological movements. In these experiments, the extensor tendon forces were greater than those of the flexors, typically by a factor of two.
引用
收藏
页码:639 / 646
页数:8
相关论文
共 16 条
[1]
A COMPARISON OF SCAPHOID-TRAPEZIUM-TRAPEZOID FUSION AND 4-BONE TENDON WEAVE FOR SCAPHOLUNATE DISSOCIATION [J].
AUGSBURGER, S ;
NECKING, L ;
HORTON, J ;
BACH, AW ;
TENCER, AF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (02) :360-369
[2]
Brand P., 1985, Clinical mechanics of the hand
[3]
GILLIOSON DB, 1988, THESIS SYRACUSE U SY
[4]
FORCE DISTRIBUTION ACROSS WRIST JOINT - APPLICATION OF PRESSURE-SENSITIVE CONDUCTIVE RUBBER [J].
HARA, T ;
HORII, E ;
AN, KN ;
COONEY, WP ;
LINSCHEID, RL ;
CHAO, EYS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (02) :339-347
[5]
AN ELECTROGONIOMETRIC STUDY OF KNEE MOTION IN NORMAL GAIT [J].
KETTELKAMP, DB ;
JOHNSON, RJ ;
SMIDT, GL ;
CHAO, EYS ;
WALKER, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (04) :775-+
[6]
ARCHITECTURE OF SELECTED MUSCLES OF THE ARM AND FOREARM - ANATOMY AND IMPLICATIONS FOR TENDON TRANSFER [J].
LIEBER, RL ;
JACOBSON, MD ;
FAZELI, BM ;
ABRAMS, RA ;
BOTTE, MJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (05) :787-798
[7]
FREQUENCY-SPECTRUM ANALYSIS OF WRIST MOTION FOR ACTIVITIES OF DAILY LIVING [J].
MANN, KA ;
WERNER, FW ;
PALMER, AK .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (02) :304-306
[8]
INTRAOPERATIVE ASSESSMENT OF WRIST EXTENSOR MUSCLE FORCE [J].
MENDELSON, LS ;
PECKHAM, PH ;
FREEHAFER, AA ;
KEITH, MW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06) :832-836
[9]
FUNCTIONAL WRIST MOTION - A BIOMECHANICAL STUDY [J].
PALMER, AK ;
WERNER, FW ;
MURPHY, D ;
GLISSON, R .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (01) :39-46
[10]
RODGERS MM, 1989, P 13 ANN M AM SOC BI, P36