Cernentless acetabular reconstruction in revision total hip arthroplasty

被引:76
作者
Della Valle, CJ [1 ]
Berger, RA [1 ]
Rosenberg, AG [1 ]
Galante, JO [1 ]
机构
[1] Rush Presbyterian St Lukes Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
关键词
D O I
10.1097/00003086-200403000-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reconstruction of the failed acetabular component in total hip arthroplasty (THA) can be challenging. Although there are multiple reconstructive options available, a cementless acetabular component inserted with screws has been shown to have good intermediate-term results and is the reconstructive method of choice for the majority of acetabular revisions. We reviewed the results of 13 8 consecutive acetabular revisions done with a hemispheric, cementless acetabular component that is sintered with Ti fiber metal mesh and was inserted with line-to-line reaming and multiple screws for fixation. At a mean of 15 years, 19 acetabular components had been revised (13.8%); seven were revised for recurrent instability, six were revised for deep periprosthetic infection, five well-fixed cups were removed at the time of femoral revision, and one cup was fixed by fibrous tissue only at the time of femoral revision and was removed. One acetabular component was radiographically loose. Survivorship of the component was 81% at 15 years when revision for any reason was considered as an end point and 96% when revision for loosening or radiographic evidence of loosening was considered as a second end point. Cementless acetabular revision provides durable results at 15 years with a low rate of failure for loosening.
引用
收藏
页码:96 / 100
页数:5
相关论文
共 21 条
[1]  
*AM AC ORTH SURG, 2002, ANTHR TOT JOINT PROC
[2]   Pelvic discontinuity in revision total hip arthroplasty [J].
Berry, DJ ;
Lewallen, DG ;
Hanssen, AD ;
Cabanela, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1692-1702
[3]  
CHAREANCHOLVANI.K, 1999, CLIN ORTHOP RELAT R, V361, P140
[4]   Acetabular revision arthroplasty using so-called jumbo cementless components - An average 7-year follow-up study [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :8-15
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]   Porous-coated cementless acetabular cups in revision surgery - A 6-to 11-year follow-up study [J].
Garcia-Cimbrelo, E .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :397-406
[8]   Jumbo cups and morselized graft [J].
Jasty, M .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (02) :249-+
[9]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[10]   Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years [J].
Lachiewicz, PF ;
Poon, ED .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :980-984