MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)

被引:33
作者
Bidinosti, CP [1 ]
Choukeife, J
Tastevin, G
Vignaud, A
Nacher, PJ
机构
[1] Simon Fraser Univ, Dept Phys, Burnaby, BC V5A 1S6, Canada
[2] Lab Kastler Brossel, F-75231 Paris, France
[3] Univ Paris 11, F-91405 Orsay, France
关键词
hyperpolarized helium; relaxation; lung; MRI; oxygen; very low field;
D O I
10.1007/s10334-004-0035-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Optical pumping of He-3 produces large (hyper) nuclear-spin polarizations independent of the magnetic resonance imaging (MRI) field strength. This allows lung MRI to be performed at reduced fields with many associated benefits, such as lower tissue susceptibility gradients and decreased power absorption rates. Here we present results of 2D imaging as well as accurate 1D gas diffusion mapping of the human lung using He-3 at very low field (3 mT). Furthermore, measurements of transverse relaxation in zero applied gradient are shown to accurately track pulmonary O-2 partial pressure, opening the way for novel imaging sequences.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 11 条
[1]   In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields [J].
Bidinosti, CP ;
Choukeife, J ;
Nacher, PJ ;
Tastevin, G .
JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (01) :122-132
[2]   Assessment of a single-acquisition imaging sequence for oxygen-sensitive 3He-MRI [J].
Deninger, AJ ;
Eberle, B ;
Bermuth, J ;
Escat, B ;
Markstaller, K ;
Schmiedeskamp, J ;
Schreiber, WG ;
Surkau, R ;
Otten, E ;
Kauczor, HU .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :105-114
[3]   CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T). [J].
Durand, E ;
Guillot, G ;
Darrasse, L ;
Tastevin, G ;
Nacher, PJ ;
Vignaud, A ;
Vattolo, D ;
Bittoun, J .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :75-81
[4]   Nuclear magnetic resonance imaging with hyperpolarised helium-3 [J].
Ebert, M ;
Grossmann, T ;
Heil, W ;
Otten, WE ;
Surkau, R ;
Leduc, M ;
Bachert, P ;
Knopp, MV ;
Schad, LR ;
Thelen, M .
LANCET, 1996, 347 (9011) :1297-1299
[5]  
HERSMAN B, 2003, UNPUB MAGN RESON MED
[6]   MRI of the lungs using hyperpolarized noble gases [J].
Möller, HE ;
Chen, XJ ;
Saam, B ;
Hagspiel, KD ;
Johnson, GA ;
Altes, TA ;
de Lange, EE ;
Kauczor, HU .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1029-1051
[7]   NUCLEAR-RELAXATION OF HE-3 IN THE PRESENCE OF O-2 [J].
SAAM, B ;
HAPPER, W ;
MIDDLETON, H .
PHYSICAL REVIEW A, 1995, 52 (01) :862-865
[8]   Hyperpolarized noble gas MR imaging of the lung: Potential clinical applications [J].
Salerno, M ;
Altes, TA ;
Mugler, JP ;
Nakatsu, M ;
Hatabu, H ;
de Lange, EE .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 40 (01) :33-44
[9]   SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT [J].
STEJSKAL, EO ;
TANNER, JE .
JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) :288-+
[10]  
SWIFT AJ, 2003, UNPUB J MAGN RESON I