Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis

被引:92
作者
Montorsi, P [1 ]
De Bernardi, F [1 ]
Muratori, M [1 ]
Cavoretto, D [1 ]
Pepi, M [1 ]
机构
[1] Univ Milan, Ctr Cardiol Fondazione Monzino, Inst Cardiol, IRCCS CNR, I-20138 Milan, Italy
关键词
D O I
10.1016/S0002-9149(99)00607-4
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Prosthetic heart valve thrombosis (PVT) is a rare but potentially life-threatening complication of heart valve replacement. An effective, quick, and easy diagnostic method is highly desirable. We evaluated the diagnostic efficacy of cine-fluoroscopy (CF), transthoracic (TTE), and transesophageal (TEE) echocardiography in 82 consecutive patients with mechanical valves and suspected PVT. Criteria for PVT were: leaflet(s) motion restriction at CF, increased Doppler gradients at TTE, and evidence of thrombi at. TEE. Patients were divided in 4 groups (A, B, C, and D) according to results of CF and TIE. Group A was composed of 24 patients with positive CF and TTE. Thrombi were detected by TEE in all cases, suggesting that when both are positive, CF and TTE correctly identified PVT in all patients so that TEE may be deferred. Group B was composed of 12 patients with positive CF and negative TTE; TEE showed PVT in 4 patients (33%). These patients had very slight leaflet motion restriction as in the case of initial PVT. This suggests that CF compared with Doppler may identify patients with "hemodynamically significant" PVT,The remaining 8 patients in this group had monocuspid prostheses with negative TEE, suggesting that abnormal leaflet motion at CF may be due to functional changes. Therefore, TEE should always be performed in case of monocuspid prostheses with isolated CF abnormalities. Group C was composed of 18 asymptomatic patients with small-sized aortic prostheses and very high Doppler gradients on routine TIE, CF showed normal leaflet motion and TEE ruled out PVT in all cases outlining the diagnostic role of CF in this particular subset. Finally, group D was composed of 28 patients with negative CF and TTE, TEE did not show thrombi in 24 of 28 patients (86%), confirming that, when both yield negative results, CF and TTE are reliable methods to rule out valve thrombosis in most cases. However, in 4 of 28 patients (14%) TEE showed "non-obstructive" prosthetic thrombosis: these patients herd mitral prostheses, chronic atrial fibrillation, and 3 of 4 had systemic embolisms. Thus, TEE should be performed in selected patients despite negative CF and TTE results. Sensitivity, specificity, and positive and negative predictive values were 87%, 78%, 80%, and 91% for CF and 75%, 64%, 57%, and 78% far TIE, respectively. CF and TTE correctly identified PVT in 70 of 82 patients (85%). TEE was actually required in 15% of the cases. Thus, CF and TTE are quick, effective, and complementary diagnostic tools to diagnose PVT in most patients. TEE still remains the gold standard technique in selected cases. (C) 2000 by Excerpta Medica, Inc.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 22 条
[1]
OBSTRUCTION OF THE ST-JUDE MEDICAL VALVE - DIAGNOSTIC AND THERAPEUTIC VALUES OF CINERADIOGRAPHY [J].
AOYAGI, S ;
HIGA, Y ;
MATSUZOE, S ;
NISHI, Y ;
TANAKA, K ;
KAWARA, T ;
ORYOJI, A ;
KOSUGA, K ;
OISHI, K .
THORACIC AND CARDIOVASCULAR SURGEON, 1993, 41 (06) :357-363
[2]
Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameters [J].
Barbetseas, J ;
Nagueh, SF ;
Pitsavos, C ;
Toutouzas, PK ;
Quinones, MA ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1410-1417
[3]
EFFECT OF PROSTHETIC VALVE MALFUNCTION ON THE DOPPLER-CATHETER GRADIENT RELATION FOR BILEAFLET AORTIC-VALVE PROSTHESES [J].
BAUMGARTNER, H ;
SCHIMA, H ;
KUHN, P .
CIRCULATION, 1993, 87 (04) :1320-1327
[4]
DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[5]
COMPARISON OF TRANSTHORACIC AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR DETECTION OF ABNORMALITIES OF PROSTHETIC AND BIOPROSTHETIC VALVES IN THE MITRAL AND AORTIC POSITIONS [J].
DANIEL, WG ;
MUGGE, A ;
GROTE, J ;
HAUSMANN, D ;
NIKUTTA, P ;
LAAS, J ;
LICHTLEN, PR ;
MARTIN, RP .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (02) :210-215
[6]
OBSTRUCTION OF MECHANICAL HEART-VALVE PROSTHESES - CLINICAL ASPECTS AND SURGICAL-MANAGEMENT [J].
DEVIRI, E ;
SARELI, P ;
WISENBAUGH, T ;
CRONJE, SL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (03) :646-650
[7]
TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR THE DIAGNOSIS AND MANAGEMENT OF NONOBSTRUCTIVE THROMBOSIS OF MECHANICAL MITRAL-VALVE PROSTHESIS [J].
GUERET, P ;
VIGNON, P ;
FOURNIER, P ;
CHABERNAUD, JM ;
GOMEZ, M ;
LACROIX, P ;
BENSAID, J .
CIRCULATION, 1995, 91 (01) :103-110
[8]
Horstkotte D, 1995, J Heart Valve Dis, V4, P141
[9]
CINERADIOGRAPHIC EVALUATION OF THE CONVEXO-CONCAVE BJORK-SHILEY PROSTHETIC VALVE IN MITRAL POSITION [J].
ISHIMARU, S ;
FURUAWKA, K ;
TAKAHASHI, M .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1983, 17 (03) :211-215
[10]
THROMBOTIC OBSTRUCTION OF DISK VALVES - CLINICAL RECOGNITION AND SURGICAL-MANAGEMENT [J].
KONTOS, GJ ;
SCHAFF, HV ;
ORSZULAK, TA ;
PUGA, FJ ;
PLUTH, JR ;
DANIELSON, GK .
ANNALS OF THORACIC SURGERY, 1989, 48 (01) :60-65