Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay

被引:173
作者
Boyce, John M. [1 ,3 ]
Havill, Nancy L. [1 ]
Dumigan, Diane G. [1 ]
Golebiewski, Michael [2 ]
Balogun, Ola [2 ]
Rizvani, Ramo [2 ]
机构
[1] Hosp St Raphael, Infect Dis Sect, New Haven, CT 06511 USA
[2] Hosp St Raphael, Environm Serv Dept, New Haven, CT 06511 USA
[3] Yale Univ, Sch Med, New Haven, CT USA
关键词
VANCOMYCIN-RESISTANT ENTEROCOCCUS; INTENSIVE-CARE-UNIT; CLOSTRIDIUM-DIFFICILE; STAPHYLOCOCCUS-AUREUS; ATP-BIOLUMINESCENCE; ENVIRONMENTAL SURFACES; CONTAMINATION; HYGIENE; RISK; STANDARDS;
D O I
10.1086/598243
中图分类号
R1 [预防医学、卫生学];
学科分类号
100235 [预防医学];
摘要
OBJECTIVE. To evaluate the usefulness of an adenosine triphosphate (ATP) bioluminescence assay for assessing the efficacy of daily hospital cleaning practices. DESIGN. A 2-phase prospective intervention study. SETTING. A university-affiliated community teaching hospital. METHODS. During phase I of our study, 5 high-touch surfaces in 20 patient rooms were sampled before and after daily cleaning. Moistened swabs were used to sample these surfaces and were then plated onto routine and selective media, and aerobic colony counts were determined after 48 hours of incubation. Specialized ATP swabs were used to sample the same high-touch surfaces in the 20 patient rooms and were then placed in luminometers, and the amount of ATP present was expressed as relative light units. During phase II of our study, after in-service housekeeper educational sessions were given, the housekeepers were told in advance when ATP readings would be taken before and after cleaning. RESULTS. During phase I, the colony counts revealed that the 5 high-touch surfaces were often not cleaned adequately. After cleaning, 24 (24%) of the 100 surface samples were still contaminated with methicillin-resistant Staphylococcus aureus, and 16 (16%) of the 100 surface samples still yielded vancomycin-resistant enterococci. ATP readings (expressed as relative light units) revealed that only bathroom grab bars and toilet seats were significantly cleaner after daily cleaning than before. During phase II, a total of 1,013 ATP readings were obtained before and after daily cleaning in 105 rooms. The median relative light unit was significantly lower (ie, surfaces were cleaner) after cleaning than before cleaning for all 5 high-touch surfaces. CONCLUSIONS. Suboptimal cleaning practices were documented by determining aerobic colony counts and by use of an ATP bioluminescence assay. ATP readings provided quantitative evidence of improved cleanliness of high-touch surfaces after the implementation of an intervention program.
引用
收藏
页码:678 / 684
页数:7
相关论文
共 29 条
[1]
UV-visible marker confirms that environmental persistence of Clostridium difficile spores in toilets of patients with C-difficile-associated diarrhea is associated with lack of compliance with cleaning protocol.e [J].
Alfa, Michelle J. ;
Dueck, Christine ;
Olson, Nancy ;
DeGagne, Pat ;
Papetti, Selena ;
Wald, Alana ;
Lo, Evelyn ;
Harding, Godfrey .
BMC INFECTIOUS DISEASES, 2008, 8 (1)
[2]
[Anonymous], 2003, MMWR-MORBID MORTAL W, V52, P1
[3]
Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen [J].
Aycicek, H ;
Oguz, U ;
Karci, K .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2006, 209 (02) :203-206
[4]
Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool [J].
Carling, P. C. ;
Von Beheren, S. ;
Kim, P. ;
Woods, C. .
JOURNAL OF HOSPITAL INFECTION, 2008, 68 (01) :39-44
[5]
Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals [J].
Carling, P. C. ;
Parry, M. F. ;
Von Beheren, S. M. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (01) :1-7
[6]
Improved cleaning of patient rooms using a new targeting method [J].
Carling, PC ;
Briggs, JL ;
Perkins, J ;
Highlander, D .
CLINICAL INFECTIOUS DISEASES, 2006, 42 (03) :385-388
[7]
Monitoring the effectiveness of cleaning in four British hospitals [J].
Cooper, Rose A. ;
Griffith, Chris J. ;
Malik, Rifhat E. ;
Obee, Peter ;
Looker, Nick .
AMERICAN JOURNAL OF INFECTION CONTROL, 2007, 35 (05) :338-341
[8]
How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals [J].
Dancer, SJ .
JOURNAL OF HOSPITAL INFECTION, 2004, 56 (01) :10-15
[9]
Mopping up hospital infection [J].
Dancer, SJ .
JOURNAL OF HOSPITAL INFECTION, 1999, 43 (02) :85-100
[10]
Davidson CA, 1999, LUMINESCENCE, V14, P33, DOI 10.1002/(SICI)1522-7243(199901/02)14:1<33::AID-BIO514>3.0.CO