Retinal assessment using optical coherence tomography

被引:173
作者
Costa, Rogerio A.
Skaf, Mirian
Melo, Luiz A. S., Jr.
Calucci, Daniela
Cardillo, Jose A.
Castro, Jarbas C.
Huang, David
Wojtkowski, Maciej
机构
[1] Hosp Olhas Araraquara, UDAT, Retina Diagnost & Treatment Div, BR-14801310 Araraquara, SP, Brazil
[2] Hosp Olhas Araraquara, Glaucoma Sect, Araraquara, SP, Brazil
[3] USP, Inst Fis Sao Carlos, Sao Carlos, SP, Brazil
[4] Univ So Calif, Dept Ophthalmol, Los Angeles, CA 90089 USA
[5] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
基金
巴西圣保罗研究基金会;
关键词
artifacts; cross-sectional; fourier domain; glaucoma; interferometer; macula; macular map; measurement; nerve fiber layer; optic disc; optical coherence tomography (OCT); photoreceptor; retinal boundary; retinal thickness; spectral;
D O I
10.1016/j.preteyeres.2006.03.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Over the 15 years since the original description, optical coherence tomography (OCT) has become one of the key diagnostic technologies in the ophthalmic subspecialty areas of retinal diseases and glaucoma. The reason for the widespread adoption of this technology originates from at least two properties of the OCT results: on the one hand, the results are accessible to the non-specialist where microscopic retinal abnormalities are grossly and easily noticeable; on the other hand, results are reproducible and exceedingly quantitative in the hands of the specialist. However, as in any other imaging technique in ophthalmology, some artifacts are expected to occur. Understanding of the basic principles of image acquisition and data processing as well as recognition of OCT limitations are crucial issues to using this equipment with cleverness. Herein, we took a brief look in the past of OCT and have explained the key basic physical principles of this imaging technology. In addition, each of the several steps encompassing a third generation OCT evaluation of retinal tissues has been addressed in details. A comprehensive explanation about next generation OCT systems has also been provided and, to conclude, we have commented on the future directions of this exceptional technique. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:325 / 353
页数:29
相关论文
共 142 条
[1]   Spinocerebellar ataxia type 7 (SCA7) shows a cone-rod dystrophy phenotype [J].
Aleman, TS ;
Cideciyan, AV ;
Volpe, NJ ;
Stevanin, G ;
Brice, A ;
Jacobson, SG .
EXPERIMENTAL EYE RESEARCH, 2002, 74 (06) :737-745
[2]  
[Anonymous], 1996, OPTICAL COHERENCE TO
[3]   Intravitreal triamcinolone for uveitic cystoid macular edema: An optical coherence tomography study [J].
Antcliff, RJ ;
Spalton, DJ ;
Stanford, MR ;
Graham, EM ;
Ffytche, TJ ;
Marshall, J .
OPHTHALMOLOGY, 2001, 108 (04) :765-772
[4]   Macular symmetry testing for glaucoma detection [J].
Bagga, H ;
Greenfield, DS ;
Knighton, RW .
JOURNAL OF GLAUCOMA, 2005, 14 (05) :358-363
[5]   AXIAL INTENSITY DISTRIBUTION ANALYSIS OF THE HUMAN RETINA WITH A CONFOCAL SCANNING LASER TOMOGRAPH [J].
BARTSCH, DU ;
FREEMAN, WR .
EXPERIMENTAL EYE RESEARCH, 1994, 58 (02) :161-173
[6]   Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[7]   Intravitreal injection versus sub-Tenon's infusion of triamcinolone acetonide for refractory diabetic macular edema: A randomized clinical trial [J].
Bonini, MA ;
Jorge, R ;
Barbosa, JC ;
Calucci, D ;
Cardillo, JA ;
Costa, RA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (10) :3845-3849
[8]  
Bowd C, 2000, ARCH OPHTHALMOL-CHIC, V118, P22
[9]  
Bowd C, 2001, INVEST OPHTH VIS SCI, V42, P1993
[10]   Comparison of the clinical diagnosis of diabetic macular edema with diagnosis by optical coherence tomography [J].
Browning, DJ ;
McOwen, MD ;
Bowen, RM ;
O'Marah, TL .
OPHTHALMOLOGY, 2004, 111 (04) :712-715