Scaling structure factor amplitudes in electron cryomicroscopy using X-ray solution scattering

被引:12
作者
Schmid, MF [1 ]
Sherman, MB
Matsudaira, P
Tsuruta, H
Chiu, W
机构
[1] Baylor Univ, Natl Ctr Macromol Imaging, Houston, TX 77030 USA
[2] Baylor Univ, Verna & Marrs Mclean Dept Biochem, Houston, TX 77030 USA
[3] MIT, Whitehead Inst Biomed Res, Dept Biol, Div Bioengn & Environm Hlth, Cambridge, MA 02142 USA
[4] Stanford Univ, Stanford Linear Accelerator Ctr, SSRL, Stanford, CA 94309 USA
关键词
D O I
10.1006/jsbi.1999.4173
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The structure factors derived from electron cryomicroscopic images are modified by the contrast transfer function of the microscope's objective lens and other influences. The phases of the structure factors can be corrected in a straightforward way when the positions of the contrast transfer function rings are determined. However, corrected amplitudes are also essential to yield an accurate distribution of mass in the reconstruction. The correct scale factors for the amplitudes are difficult to evaluate for data that are merged from many different micrographs. We opt to use X-ray solution scattering intensity from a concentrated suspension of the specimen to correct the amplitudes of the spherically averaged structure factors. When this approach is applied to the three-dimensional image data of ice-embedded acrosomal bundles, the core of a filament in a three-dimensional reconstruction of the acrosomal bundle becomes denser and matches more closely the outer density ascribed to scruin, (C) 1999 Academic Press.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 1971, ELECT MICROSCOPY MAT
[2]   Visualization of beta-sheets and side-chain clusters in two-dimensional periodic arrays of streptavidin on phospholipid monolayers by electron crystallography [J].
AvilaSakar, AJ ;
Chiu, W .
BIOPHYSICAL JOURNAL, 1996, 70 (01) :57-68
[3]   Determination of the fold of the core protein of hepatitis B virus ky electron cryomicroscopy [J].
Bottcher, B ;
Wynne, SA ;
Crowther, RA .
NATURE, 1997, 386 (6620) :88-91
[4]   DATA ACQUISITION-SYSTEMS FOR LINEAR AND AREA X-RAY-DETECTORS USING DELAY-LINE READOUT [J].
BOULIN, CJ ;
KEMPF, R ;
GABRIEL, A ;
KOCH, MHJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01) :312-320
[5]   Evaluation of charging on macromolecules in electron cryomicroscopy [J].
Brink, J ;
Sherman, MB ;
Berriman, J ;
Chiu, W .
ULTRAMICROSCOPY, 1998, 72 (1-2) :41-52
[6]  
CHIU W, 1977, ULTRAMICROSCOPY, V2, P207
[7]   OBSERVATIONS OF RESTRICTED BEAM-INDUCED SPECIMEN MOTION WITH SMALL-SPOT ILLUMINATION [J].
DOWNING, KH .
ULTRAMICROSCOPY, 1988, 24 (04) :387-398
[8]  
DOWNING KH, 1982, ULTRAMICROSCOPY, V7, P384
[10]   LINEAR, CIRCULAR AND 2 DIMENSIONAL POSITION-SENSITIVE DETECTORS [J].
GABRIEL, A ;
DAUVERGNE, F ;
ROSENBAUM, G .
NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (01) :191-194