Torsional fatigue and endurance limit of a size 30.06 ProFile rotary instrument

被引:28
作者
Best, S
Watson, P
Pilliar, R
Kulkarni, GGK
Yared, G
机构
[1] Univ Toronto, Fac Dent, Dept Endodont, Toronto, ON M5G 1G6, Canada
[2] Univ Toronto, Fac Dent, Dept Biomat, Toronto, ON M5G 1G6, Canada
[3] Univ Toronto, Fac Dent, Dept Pediat Dent, Toronto, ON M5G 1G6, Canada
关键词
endurance limit; nickel-titanium; torsional fatigue;
D O I
10.1111/j.1365-2591.2004.00814.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the torsional cyclic fatigue characteristics and specifically the endurance limit (EL) of a nickel-titanium rotary instrument. Methodology Size 30.06 taper ProFile instruments were evaluated. The equipment was assembled according to the ANSI/ADA Specification No. 28. The motor was programmed to repeatedly rotate to a selected deflection angle (DA) and then return to zero (cycle). Testing started at 200degrees and was continued at decreasing angles until 10(6) cycles were reached without instrument fracture. Ten instruments were tested at each DA. The mean log number of cycles to fracture and standard deviation were determined for each DA at which fracture occurred. The DA at which 10(6) cycles were reached without instrument fracture corresponded by definition to the EL. Analysis of variance and pairwise comparisons using Duncan's multiple range test were performed to detect significant differences among the mean log number of cycles of the different DA. Significance was determined at the 95% confidence level. Results Instruments cycled at larger DA consistently demonstrated fewer cycles to fracture than those cycled at smaller DA. The differences among the mean log number of cycles of the different DA were statistically significant (P < 0.001). Cycles of 10(6) were completed without instrument fracture at 2.5degrees. Conclusions A torsional fatigue profile was generated for a specific NiTi rotary instrument. The EL was 2.5degrees.
引用
收藏
页码:370 / 373
页数:4
相关论文
共 16 条
[11]  
TAPLEY BD, 1990, ESCHBACHS HDB ENG FU
[12]   Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models [J].
Turpin, YL ;
Chagneau, F ;
Vulcain, JM .
JOURNAL OF ENDODONTICS, 2000, 26 (07) :414-417
[13]   AN INITIAL INVESTIGATION OF THE BENDING AND TORSIONAL PROPERTIES OF NITINOL ROOT-CANAL FILES [J].
WALIA, H ;
BRANTLEY, WA ;
GERSTEIN, H .
JOURNAL OF ENDODONTICS, 1988, 14 (07) :346-351
[14]  
WESTON C, 1994, P BR SOC DENT MAXILL, V6, P9
[15]   Cyclic fatigue of Profile rotary instruments after clinical use [J].
Yared, GM ;
Dagher, FEB ;
Machtou, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (03) :204-207
[16]   Cyclic fatigue of Profile rotary instruments after simulated clinical use [J].
Yared, GM ;
Dagher, FEB ;
Machtou, P .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (02) :115-119