Dual fluorescence and electrochemical detection on an electrophoresis microchip

被引:75
作者
Lapos, JA [1 ]
Manica, DP [1 ]
Ewing, AG [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16802 USA
关键词
D O I
10.1021/ac025504p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous amperometitic and fluorescence detection in a microfabricated electrophoresis chip is reported. Detection limits of 448 nM and 1.52, 16, and 28 muM have been achieved for dopamine, catechol, NBD-arginine, and NBD-phenylalanine, respectively. These two orthogonal detection schemes allow analysis of a wider spectrum of compounds per separation, leading to higher throughput and enabling resolution of two neutral analytes, NBD-arginine and catechol. In addition, insight into the detection and separation mechanisms is realized. Differences in migration time and peak widths between the two detectors are compared, providing a better understanding of detector alignment. A common problem encountered in electrophoresis is run-to-run migration time irreproducibility for certain samples. This novel microchip dual detection system has been utilized to reduce this irreproducibility. An unknown sample is monitored with one detector while a standard (i.e., ladder) is added to the sample and monitored simultaneously with the other detector. This dual detection method is demonstrated to normalize unknown peak mobilities in a cerebral spinal fluid sample.
引用
收藏
页码:3348 / 3353
页数:6
相关论文
共 51 条
[1]   ANALYSIS OF HUMAN CEREBROSPINAL-FLUID BY CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE DETECTION [J].
BERGQUIST, J ;
GILMAN, SD ;
EWING, AG ;
EKMAN, R .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3512-3518
[2]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[3]  
2-M
[4]   Holographic refractive index detector for application in microchip-based separation systems [J].
Burggraf, N ;
Krattiger, B ;
de Mello, AJ ;
de Rooij, NF ;
Manz, A .
ANALYST, 1998, 123 (07) :1443-1447
[5]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[6]   SELECTIVE RETENTION OF CATECHOLAMINES AND THEIR DERIVATIVES IN REVERSED-PHASE ION-PAIR PARTITION CHROMATOGRAPHY [J].
DEJONG, J ;
VANVALKENBURG, CFM ;
TJADEN, UR .
JOURNAL OF CHROMATOGRAPHY, 1985, 322 (01) :43-53
[7]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[8]  
2-7
[9]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[10]   USE OF NBD CHLORIDE (7 CHLORO-4-NITROBENZO-2-OXA-1,3-DIAZOLE) IN DETECTING AMINO-ACIDS AND AS AN N-TERMINAL REAGENT [J].
FAGER, RS ;
KUTINA, CB ;
ABRAHAMSON, EW .
ANALYTICAL BIOCHEMISTRY, 1973, 53 (01) :290-294