Dual fluorescence and electrochemical detection on an electrophoresis microchip

被引:75
作者
Lapos, JA [1 ]
Manica, DP [1 ]
Ewing, AG [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16802 USA
关键词
D O I
10.1021/ac025504p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous amperometitic and fluorescence detection in a microfabricated electrophoresis chip is reported. Detection limits of 448 nM and 1.52, 16, and 28 muM have been achieved for dopamine, catechol, NBD-arginine, and NBD-phenylalanine, respectively. These two orthogonal detection schemes allow analysis of a wider spectrum of compounds per separation, leading to higher throughput and enabling resolution of two neutral analytes, NBD-arginine and catechol. In addition, insight into the detection and separation mechanisms is realized. Differences in migration time and peak widths between the two detectors are compared, providing a better understanding of detector alignment. A common problem encountered in electrophoresis is run-to-run migration time irreproducibility for certain samples. This novel microchip dual detection system has been utilized to reduce this irreproducibility. An unknown sample is monitored with one detector while a standard (i.e., ladder) is added to the sample and monitored simultaneously with the other detector. This dual detection method is demonstrated to normalize unknown peak mobilities in a cerebral spinal fluid sample.
引用
收藏
页码:3348 / 3353
页数:6
相关论文
共 51 条
[41]   Microchip flow cytometry using electrokinetic focusing [J].
Schrum, DP ;
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4173-4177
[42]   Radial capillary array electrophoresis microplate and scanner for high-performance nucleic acid analysis [J].
Shi, YN ;
Simpson, PC ;
Scherer, JR ;
Wexler, D ;
Skibola, C ;
Smith, MT ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5354-5361
[43]   High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates [J].
Simpson, PC ;
Roach, D ;
Woolley, AT ;
Thorsen, T ;
Johnston, R ;
Sensabaugh, GF ;
Mathies, RA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (05) :2256-2261
[44]  
STEINBERG H, 1964, ORGANOBORON CHEM, pCH6
[45]   Method for fabrication of microfluidic systems in glass [J].
Stjernstrom, M ;
Roeraade, J .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (01) :33-38
[46]   Isotachophoretic separations on a microchip. Normal Raman spectroscopy detection [J].
Walker, PA ;
Morris, MD ;
Burns, MA ;
Johnson, BN .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3766-3769
[47]   Micromachined electrophoresis chips with thick-film electrochemical detectors [J].
Wang, J ;
Tian, BM ;
Sahlin, E .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5436-5440
[48]   Capillary electrophoresis chips with integrated electrochemical detection [J].
Woolley, AT ;
Lao, KQ ;
Glazer, AN ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :684-688
[49]   ULTRA-HIGH-SPEED DNA FRAGMENT SEPARATIONS USING MICROFABRICATED CAPILLARY ARRAY ELECTROPHORESIS CHIPS [J].
WOOLLEY, AT ;
MATHIES, RA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (24) :11348-11352
[50]   A microfabricated dialysis device for sample cleanup in electrospray ionization mass spectrometry [J].
Xu, NX ;
Lin, YH ;
Hofstadler, SA ;
Matson, D ;
Call, CJ ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1998, 70 (17) :3553-3556