Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the inner tracking system of HERA-B

被引:20
作者
Bagaturia, Y
Baruth, O
Dreis, HB
Eisele, F
Gorbunov, I
Gradl, S
Gradl, W
Hausmann, S
Hildebrandt, M
Hott, T
Keller, S
Krauss, C
Lomonosov, B
Negodaev, M
Richter, C
Robmann, P
Schmid, B
Straumann, U
Truöl, P
Visbeck, S
Walter, T
Werner, C
Werthenbach, U
Zech, G [1 ]
Zeuner, T
Ziegler, M
机构
[1] Univ Siegen, FB 7, D-57068 Siegen, Germany
[2] DESY, D-2000 Hamburg, Germany
[3] Heidelberg Univ, D-6900 Heidelberg, Germany
[4] Univ Zurich, CH-8006 Zurich, Switzerland
关键词
MSGC; MSGC-GEM; gas aging; discharges; HERA-B;
D O I
10.1016/S0168-9002(02)01002-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The results of 5 years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about (20 x 20) cm(2) each. The detector is based on microstrip gas counters (MSGCs) with diamond-like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on the operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long-term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:223 / 242
页数:20
相关论文
共 25 条
[1]   Performance of GEM detectors in high intensity particle beams [J].
Bachmann, S ;
Bressan, A ;
Ketzer, B ;
Deutel, M ;
Ropelewski, L ;
Sauli, F ;
Bondar, A ;
Buzulutskov, A ;
Shekhtman, L ;
Sokolov, A ;
Tatarinov, A ;
Vasil'ev, A ;
Kappler, S ;
Schulte, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (03) :548-561
[2]   Charge amplification and transfer processes in the gas electron multiplier [J].
Bachmann, S ;
Bressan, A ;
Ropelewski, L ;
Sauli, F ;
Sharma, A ;
Mörmann, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3) :376-408
[3]  
BATEMAN, 1995, RALTR95032
[4]  
BATEMAN JE, 1994, RAL94114
[5]  
BAYATIAN G, 1998, 5 CMS TDR
[6]   Carbon coated gas electron multipliers [J].
Beirle, S ;
Werthenbach, U ;
Zech, G ;
Zeuner, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (2-3) :297-302
[7]   PERFORMANCE OF GAS MICROSTRIP CHAMBERS ON GLASS SUBSTRATA WITH ELECTRONIC CONDUCTIVITY [J].
BOUCLIER, R ;
MILLION, G ;
ROPELEWSKI, L ;
SAULI, F ;
PESTOV, YN ;
SHEKHTMAN, LI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2) :100-106
[8]   High rate behavior and discharge limits in micro-pattern detectors [J].
Bressan, A ;
Hoch, M ;
Pagano, P ;
Ropelewski, L ;
Sauli, F ;
Biagi, S ;
Buzulutskov, A ;
Gruwé, M ;
De Lentdecker, G ;
Moermann, D ;
Sharma, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 424 (2-3) :321-342
[9]  
*CMS COLL, 1994, 9420 CERNLHCC CMS CO
[10]  
DREIS HB, TRAC98060 LHCB