Clinical outcomes of short hook wire and suture marking system in thoracoscopic resection for pulmonary nodules

被引:151
作者
Miyoshi, Kentaroh [1 ]
Toyooka, Shinichi [1 ]
Gobara, Hideo [2 ]
Oto, Takahiro [1 ]
Mimura, Hidefumi [2 ]
Sano, Yoshifumi [1 ]
Kanazawa, Susumu [2 ]
Date, Hiroshi [3 ]
机构
[1] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Canc & Thorac Surg, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Radiol, Okayama 7008558, Japan
[3] Kyoto Univ, Dept Thorac Surg, Kyoto, Japan
关键词
Short hook wire and suture system; Video-assisted thoracic surgery (VATS); Localization; COMPUTED-TOMOGRAPHY; LUNG RESECTION; LOCALIZATION; LESIONS; CT; FLUOROSCOPY; GUIDANCE; EXPERIENCE; PROGNOSIS; EMBOLISM;
D O I
10.1016/j.ejcts.2009.03.039
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objective: The short hook wire and suture marking system is a device for localization of small pulmonary nodules in thoracoscopic resection. We and other authors have shown the feasibility of the marking procedure. In this study, we reviewed our recent experience to examine the problems for resecting procedure using the device and determine if the system negatively impacts the survival rates for lung cancers. Methods: Between November 1996 and March 2007, a total of 125 pulmonary nodular lesions in 108 patients were intended for thoracoscopic resection after localization with computed tomography-guided short hook wire and suture placement. We reviewed the major problems during surgery among all cases and prognosis in 64 patients with primary lung cancer. Results: One hundred and seventeen lesions (93.6%) were successfully resected by intitial resection with no major complication. However, we experienced missing events, the major problem during surgery, which was defined as temporarily missing lesions or hook wires. Eight missing events (6.4%) consisting of five unresected lesions and three remaining hook wires occurred after initial wedge resection. All the missing lesions and one remaining hook wire were recovered by additional resection. No specific factors of lesions, including location, diameter, distance from the pleural surface, and opacification were related to incidence of the 'missing event'. Five-year survival of patients with stage IA lung cancer was 90.0% with no local recurrence. Conclusions: Our localization method assured a consistent quality of resection regardless of the lesion characteristics and a reasonable prognosis for patients with primary lung cancer. The short hook wire and suture system provides acceptable utility in thoracoscopic surgery. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:378 / 382
页数:5
相关论文
共 27 条
[1]
Thoracoscopic lung resection for extremely small nodular lesions using simultaneous intraoperative real-time computed tomography [J].
Akamatsu, H ;
Sunamori, M ;
Katsuo, K .
THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (01) :34-35
[2]
[Anonymous], 2004, Pathology and Genetics of Tumours of the Urinary System and Male Genital Organs
[3]
COMPUTED TOMOGRAPHY-GUIDED COIL INJECTION AND THORACOSCOPIC PULMONARY RESECTION UNDER ROENTGENOGRAPHIC FLUOROSCOPY [J].
ASAMURA, H ;
KONDO, H ;
NARUKE, T ;
TSUCHIYA, R ;
WAKAO, F ;
KANEKO, M ;
SUEMASU, K .
ANNALS OF THORACIC SURGERY, 1994, 58 (05) :1542-1544
[4]
A novel technique for localization and excisional biopsy of small or ill-defined pulmonary lesions [J].
Daniel, TM ;
Altes, TA ;
Rehm, PK ;
Williams, MB ;
Jones, DR ;
Stolin, AV ;
Gay, SB .
ANNALS OF THORACIC SURGERY, 2004, 77 (05) :1756-1762
[5]
Preoperative localization of small pulmonary lesions with a short hook wire and suture system: Experience with 168 procedures [J].
Dendo, S ;
Kanazawa, S ;
Ando, A ;
Hyodo, T ;
Kouno, Y ;
Yasui, K ;
Mimura, H ;
Akaki, S ;
Kuroda, M ;
Shimizu, N ;
Hiraki, Y .
RADIOLOGY, 2002, 225 (02) :511-518
[6]
Sonographic guidance for the localization of peripheral pulmonary nodules during thoracoscopy [J].
Greenfield, AL ;
Steiner, RM ;
Liu, JB ;
Cohn, HE ;
Goldberg, BB ;
Rawool, NM ;
Merton, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) :1057-1060
[7]
Massive gas embolism during pulmonary nodule hook wire localization [J].
Horan, TA ;
Pinheiro, PM ;
Araújo, LM ;
Santiago, FF ;
Rodrigues, MR .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1647-1649
[8]
Localization of pulmonary nodules for thoracoscopic resection: Experience with a system using a short hookwire and suture [J].
Kanazawa, S ;
Ando, A ;
Yasui, K ;
Mitani, M ;
Hiraki, Y ;
Shimizu, N ;
Hamanaka, D ;
Kojima, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :332-334
[9]
LOCALIZATION OF SMALL PULMONARY NODULES FOR THORACOSCOPIC RESECTION - USE OF A NEWLY DEVELOPED HOOKWIRE SYSTEM [J].
KANAZAWA, S ;
ANDO, A ;
YASUI, K ;
TANAKA, A ;
HIRAKI, Y .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (02) :122-124
[10]
METHYLENE-BLUE GUIDANCE FOR SIMPLIFIED RESECTION OF A LUNG LESION [J].
KERRIGAN, DC ;
SPENCE, PA ;
CRITTENDEN, MD ;
TRIPP, MD .
ANNALS OF THORACIC SURGERY, 1992, 53 (01) :163-164