Quantitative resolution of overlapping tailing peaks obtained by diode-array detector high performance liquid chromatography in the absence of pure standards using simple chemical knowledge

被引:12
作者
Airiau, CY [1 ]
Brereton, RG [1 ]
Dunkerley, S [1 ]
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
关键词
D O I
10.1039/a908401k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The diode-array high performance liquid chromatograms of 10 samples of various mixtures of the polyaromatic hydrocarbons 1,2-benzanthracene and chrysene were recorded in different proportions ranging from 1:1 to 1:0.001. A new approach to deconvolution based upon determining purity curves, correct selection of points in time and wavelengths, and multiple linear regression is proposed. The key to the algorithm is to select those statistically acceptable solutions for which the recovered spectra are positive and the chromatographic peaks are unimodal. It is shown that these two constraints reduce the range of solutions significantly and in eight of the samples result also in good estimates of relative chromatographic peak area, demonstrating that simple chemical information when combined with statistical methods can result in quantitative resolution in the absence of external standards.
引用
收藏
页码:833 / 842
页数:10
相关论文
共 19 条