Pulstrodes: Triple pulse control of potentiometric sensors

被引:77
作者
Makarychev-Mikhailov, S [1 ]
Shvarev, A [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
关键词
D O I
10.1021/ja047728q
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ion-selective electrode membranes based on hydrophobic materials doped with chemically selective host molecules are an attractive sensing technology but normally suffer from a limited sensitivity, given by the Nernst equation, and a direct reliance on the reference electrode potential, which makes miniaturization difficult. These fundamental problems are addressed here by imposing a multipulse electrochemical excitation signal onto ion-selective membranes that lack ion-exchange properties. Current pulses are responsible for the generation of ion fluxes in the direction of the membrane, which give reproducible super-Nernstian response slopes that originate from depletion processes at the membrane surface. Membranes may also be measured at zero current after this pulse, giving super-Nernstian response regions at lower concentrations. Difference potentials obtained from subsequent pulses give about 10-fold higher sensitivities than predicted on the basis of the Nernst equation. Copyright © 2004 American Chemical Society.
引用
收藏
页码:10548 / 10549
页数:2
相关论文
共 17 条
[1]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[2]   How do pulsed amperometric ion sensors work? A simple PDE model [J].
Bakker, E ;
Meir, AJ .
SIAM REVIEW, 2003, 45 (02) :327-344
[3]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[4]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[5]   Rational design of potentiometric trace level ion sensors.: A Ag+-selective electrode with a 100 ppt detection limit [J].
Ceresa, A ;
Radu, A ;
Peper, S ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4027-4036
[6]   Direct potentiometric information on total ionic concentrations [J].
Ceresa, A ;
Pretsch, E ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2050-2054
[7]   EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES [J].
DIAMOND, D ;
MCENROE, E ;
MCCARRICK, M ;
LEWENSTAM, A .
ELECTROANALYSIS, 1994, 6 (11-12) :962-971
[8]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[9]   FARADAIC ION TRANSFER ACROSS THE INTERFACE OF 2 IMMISCIBLE ELECTROLYTE-SOLUTIONS - CHRONOPOTENTIOMETRY AND CYCLIC VOLTAMMETRY [J].
HOMOLKA, D ;
HUNG, LQ ;
HOFMANOVA, A ;
KHALIL, MW ;
KORYTA, J ;
MARECEK, V ;
SAMEC, Z ;
SEN, SK ;
VANYSEK, P ;
WEBER, J ;
BREZINA, M ;
JANDA, M ;
STIBOR, I .
ANALYTICAL CHEMISTRY, 1980, 52 (11) :1606-1610
[10]  
Jadhav S, 2000, ELECTROANAL, V12, P1251, DOI 10.1002/1521-4109(200011)12:16<1251::AID-ELAN1251>3.0.CO