Numerical simulation research to both the external fixation surgery scheme of intertrochanteric fracture and the healing process, and its clinical application
被引:10
作者:
论文数: 引用数:
h-index:
机构:
Wang, Xian-Kang
[1
]
论文数: 引用数:
h-index:
机构:
Ye, Jin-Duo
[1
]
Gu, Fu-Shun
论文数: 0引用数: 0
h-index: 0
机构:
Tianjin Univ Chinese Med, Affiliated Hosp 2, Tianjin 300150, Peoples R ChinaTianjin Univ Technol, Sch Mech Engn, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin 300384, Peoples R China
Gu, Fu-Shun
[2
]
Wang, Ai-guo
论文数: 0引用数: 0
h-index: 0
机构:
Tianjin Univ Chinese Med, Affiliated Hosp 2, Tianjin 300150, Peoples R ChinaTianjin Univ Technol, Sch Mech Engn, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin 300384, Peoples R China
Wang, Ai-guo
[2
]
论文数: 引用数:
h-index:
机构:
Zhang, Chun-Qiu
[1
]
论文数: 引用数:
h-index:
机构:
Tian, Qian-Qian
[1
]
论文数: 引用数:
h-index:
机构:
Li, Xue
[1
]
论文数: 引用数:
h-index:
机构:
Dong, Li-Min
[1
]
机构:
[1] Tianjin Univ Technol, Sch Mech Engn, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin 300384, Peoples R China
[2] Tianjin Univ Chinese Med, Affiliated Hosp 2, Tianjin 300150, Peoples R China
single arm external fixation;
the femoral intertrochanteric fracture;
stress distribution;
numerical simulation;
surgery scheme;
FEMUR;
D O I:
10.3233/BME-130850
中图分类号:
R318 [生物医学工程];
学科分类号:
100103 [病原生物学];
摘要:
In this paper, the single arm external fixation of intertrochanteric fracture healing process after surgery was simulated to obtain a postoperative fracture healing and stress distribution in the external fixator. Firstly CT images of intertrochanteric fracture are reconstructed into the femur solid model. Then based, the external fixator is installed on the model, which lastly formed a finite element model of unilateral external fixation for intertrochanteric fracture. The calculated results show: during the beginning of the fracture healing, there is much higher stress in both screws and femur in the model with solid screws than that in the model with hollow screw. The stress of the femur in the model with hollow screw is more evenly. During the middle time of Fracture healing, stress in the femoral head significantly decreases. And the stress at fracture site gradually increased with the healing occurrence. According to the results, the authors designed hollow screws to use external fixation surgery. Surgery confirmed that the use of hollow screws in fractures treatment can satisfy the strength requirements, and can effectively reduce operative time, less patient suffering. The research for external fixation can provide a reference, and promote the use of external fixation hollow screws.
机构:
Eastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, EnglandEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Lidder, Surjit
;
Heidari, Nima
论文数: 0引用数: 0
h-index: 0
机构:
Bristol Royal Infirm & Gen Hosp, Limb Reconstruct Unit, Bristol BS2 8HW, Avon, EnglandEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Heidari, Nima
;
Gaensslen, Axel
论文数: 0引用数: 0
h-index: 0
机构:
Klinikum Stadt Wolfsburg, Klin Unfallchirurg Orthopadie & Handchirurg, D-38440 Wolfsburg, GermanyEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Gaensslen, Axel
;
Grechenig, Wolfgang
论文数: 0引用数: 0
h-index: 0
机构:
Med Univ Graz, Dept Traumatol, A-8036 Graz, AustriaEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
机构:
Eastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, EnglandEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Lidder, Surjit
;
Heidari, Nima
论文数: 0引用数: 0
h-index: 0
机构:
Bristol Royal Infirm & Gen Hosp, Limb Reconstruct Unit, Bristol BS2 8HW, Avon, EnglandEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Heidari, Nima
;
Gaensslen, Axel
论文数: 0引用数: 0
h-index: 0
机构:
Klinikum Stadt Wolfsburg, Klin Unfallchirurg Orthopadie & Handchirurg, D-38440 Wolfsburg, GermanyEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England
Gaensslen, Axel
;
Grechenig, Wolfgang
论文数: 0引用数: 0
h-index: 0
机构:
Med Univ Graz, Dept Traumatol, A-8036 Graz, AustriaEastbourne Dist Gen Hosp, Eastbourne BN21 2UD, E Sussex, England