Comparison of Three-Dimensional Pseudo-continuous Arterial Spin Labeling Perfusion Imaging With Gradient-Echo and Spin-Echo Dynamic Susceptibility Contrast MRI

被引:61
作者
Wong, Alex M. [1 ,2 ]
Yan, Feng-Xian [3 ]
Liu, Ho-Ling [1 ,3 ,4 ]
机构
[1] Chang Gung Mem Hosp Keelung, Linkou Med Ctr, Dept Med Imaging & Intervent, Kaohsiung, Taiwan
[2] Chang Gung Univ, Coll Med, Tao Yuan 333, Taiwan
[3] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Coll Med, Tao Yuan 333, Taiwan
[4] Chang Gung Univ, Hlth Aging Res Ctr, Tao Yuan 333, Taiwan
关键词
MRI; perfusion; dynamic susceptibility contrast (DSC); arterial spin labeling (ASL); pseudo-continuous ASL (PCASL); CEREBRAL-BLOOD-FLOW; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; ENHANCED MRI; TRANSIT-TIME; BRAIN-TUMORS; ACUTE STROKE; GLIOMAS; VOLUME; SIGNAL;
D O I
10.1002/jmri.24178
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
PurposeTo compare the relative cerebral blood flow (CBF) obtained by pseudo-continuous arterial spin labeling sequence incorporated with volumetric fast spin-echo readout (3D-PCASL) with those by gradient-echo (GE) and spin-echo (SE) dynamic susceptibility contrast (DSC) MRI. Materials and MethodsThirty patients with various neurological diseases participated in this study. In addition to 3D-PCASL, 15 patients received GE-DSC and the others received SE-DSC imaging on a 3 Tesla scanner. A cortical gray matter (GM) to white matter (WM) and a thalamus (TM) to WM CBF ratio were determined from each perfusion scan. In addition, histograms of relative CBF distributions were obtained from each method for comparison. ResultsSignificant correlations of CBF ratios were found between 3D-PCASL and the two DSC methods (P<0.05). The 3D-PCASL resulted in GM/WM CBF ratios similar to SE-DSC but significantly smaller than GE-DSC (P=2.3 x 10(-7)). TM/WM CBF ratio obtained by 3D-PCASL was significantly smaller than those by GE- and SE-DSC (P=4.1 x 10(-7) and 1.2 x 10(-6), respectively). The histogram of relative CBF maps obtained from SE-DSC, after applied spatial smoothing, agreed well with that from 3D-PCASL. ConclusionThis study suggested that perfusion images obtained from 3D-PCASL exhibited significant correlations with DSC-MRI, with greater microvascular weighting like SE-DSC. J. Magn. Reson. Imaging 2014;39:427-433. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:427 / 433
页数:7
相关论文
共 32 条
[1]
Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[2]
Whole-Brain Arterial Spin Labeling Perfusion MRI in Patients With Acute Stroke [J].
Bokkers, Reinoud P. H. ;
Hernandez, Daymara A. ;
Merino, Jose G. ;
Mirasol, Raymond V. ;
van Osch, Matthias J. ;
Hendrikse, Jeroen ;
Warach, Steven ;
Latour, Lawrence L. .
STROKE, 2012, 43 (05) :1290-1294
[3]
Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies [J].
Boxerman, JL ;
Rosen, BR ;
Weisskoff, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :528-537
[4]
MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[5]
Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling [J].
Chalela, JA ;
Alsop, DC ;
Gonzalez-Atavales, JB ;
Maldjian, JA ;
Kasner, SE ;
Detre, JA .
STROKE, 2000, 31 (03) :680-687
[6]
Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields [J].
Dai, Weiying ;
Garcia, Dairon ;
de Bazelaire, Cedric ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1488-1497
[7]
Pseudocontinuous Arterial Spin Labeling Quantifies Relative Cerebral Blood Flow in Acute Stroke [J].
Hernandez, Daymara A. ;
Bokkers, Reinoud P. H. ;
Mirasol, Raymond V. ;
Luby, Marie ;
Henning, Erica C. ;
Merino, Jose G. ;
Warach, Steven ;
Latour, Lawrence L. .
STROKE, 2012, 43 (03) :753-758
[8]
Quantitative Blood Flow Measurements in Gliomas Using Arterial Spin-Labeling at 3T: Intermodality Agreement and Inter- and Intraobserver Reproducibility Study [J].
Hirai, T. ;
Kitajima, M. ;
Nakamura, H. ;
Okuda, T. ;
Sasao, A. ;
Shigematsu, Y. ;
Utsunomiya, D. ;
Oda, S. ;
Uetani, H. ;
Morioka, M. ;
Yamashita, Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) :2073-2079
[9]
Arterial Spin Labeling at 3.0 Tesla in Subacute Ischemia Comparison to Dynamic Susceptibility Perfusion [J].
Huck, S. ;
Kerl, H. U. ;
Al-Zghloul, M. ;
Groden, C. ;
Noelte, I. .
CLINICAL NEURORADIOLOGY, 2012, 22 (01) :29-37
[10]
Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging [J].
Jarnum, Hanna ;
Steffensen, Elena G. ;
Knutsson, Linda ;
Frund, Ernst-Torben ;
Simonsen, Carsten Wiberg ;
Lundbye-Christensen, Soren ;
Shankaranarayanan, Ajit ;
Alsop, David C. ;
Jensen, Finn Taagehoj ;
Larsson, Elna-Marie .
NEURORADIOLOGY, 2010, 52 (04) :307-317