Accelerated micro-sequential injection in lab-on-valve format, applied to enzymatic assays

被引:20
作者
Chen, Y [1 ]
Ruzicka, J [1 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
D O I
10.1039/b401831a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The assay cycle of sequential injection ( SI) analysis has been greatly accelerated by simultaneously processing two sample injections within the same manifold. This is achieved through micro-miniaturization of the SI system using the lab-on-valve format (LOV), and by optimizing the assay protocol for stopped-flow reaction rate measurements. The approach has been tested on enzymatic assays of glucose and ethanol, but it is, in principle, applicable to all SI reagent-based assays. The average assay time for a single run has been shortened from 200 s to approximate to 30 s. Assays were carried out at 22 degreesC and 37 degreesC using commercially available reagent kits. For glucose, at 22 degreesC, the calibration had a linear response (r(2) = 0.9999) for the concentration range of 100 - 1000 ppm. At 37 degreesC, the calibration was linear (r(2) = 0.9996) for 100 - 600 ppm glucose, but was a second order polynomial curve (r(2) = 0.9996) for 100 - 1000 ppm. For ethanol, at both 22 degreesC and 37 degreesC, the calibrations were linear for the concentration range of 50 - 250 ppm. The r(2) at two temperatures was 0.9994 and 0.9995, respectively. For both the glucose and ethanol assays, the relative standard deviations were below 3%. Factors affecting sampling frequency are discussed. In this work, sequential injection is shown, for the first time, to achieve sampling frequency comparable to flow injection (FI), while retaining the advantages of small reagent consumption ( typically microlitres per assay), minimized waste production, full automation of assay protocols, and zero carryover.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 8 条
[1]   Sequential injection analysis [J].
Lenehan, CE ;
Barnett, NW ;
Lewis, SW .
ANALYST, 2002, 127 (08) :997-1020
[2]   PRINCIPLES OF STOPPED-FLOW SEQUENTIAL INJECTION-ANALYSIS AND ITS APPLICATION TO THE KINETIC DETERMINATION OF TRACES OF A PROTEOLYTIC-ENZYME [J].
RUZICKA, J ;
GUBELI, T .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1680-1685
[3]   SEQUENTIAL INJECTION - A NEW CONCEPT FOR CHEMICAL SENSORS, PROCESS ANALYSIS AND LABORATORY ASSAYS [J].
RUZICKA, J ;
MARSHALL, GD .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :329-343
[4]   Lab-on-valve: universal microflow analyzer based on sequential and bead injection [J].
Ruzicka, J .
ANALYST, 2000, 125 (06) :1053-1060
[5]  
RUZICKA J, 2002, FLOW INJECTION TUTOR
[6]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd
[7]   Real-time determination of glucose consumption by live cells using a lab-on-valve system with an integrated microbioreactor [J].
Schulz, CM ;
Ruzicka, J .
ANALYST, 2002, 127 (10) :1293-1298
[8]   Micro sequential injection: fermentation monitoring of ammonia, glycerol, glucose, and free iron using the novel lab-on-valve system [J].
Wu, CH ;
Scampavia, L ;
Ruzicka, J ;
Zamost, B .
ANALYST, 2001, 126 (03) :291-297