Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry

被引:297
作者
Sampson, Jason S. [1 ]
Hawkridge, Adam M. [1 ]
Muddiman, David C. [1 ]
机构
[1] N Carolina State Univ, Dept Chem, FT, ICR,Mass Spect Lab, Raleigh, NC 27695 USA
关键词
D O I
10.1016/j.jasms.2006.08.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the coupling of a hybrid ionization source, matrix-assisted laser desorption electrospray ionization (MALDESI), to a Fourier transform-ion cyclotron resonance mass spectrometer (FT-ICR MS). The details of the source design and initial data are presented. Analysis of peptides and proteins ranging from 1 to 8.6 kDa resulted in high resolving power single-acquisition FT-ICR mass spectra with average charge-states highly correlated to those obtained by nanoESI, thus, providing strong evidence that the ESI process dictates the observed charge-state distribution. Importantly, unlike the recently introduced electrospray assisted laser desorption ionization (ELDI) source reported by Shiea and coworkers [1, 2], the data we have obtained to date rely on the use of an organic acid matrix. The results presented herein provide insight into the charging mechanism of this emerging ionization approach, while also expanding the utility of FT-ICR MS for top-down protein and complex mixture analysis.
引用
收藏
页码:1712 / 1716
页数:5
相关论文
共 24 条
[1]  
Bergen HR, 2003, DIS MARKERS, V19, P239
[2]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[3]   Laser desorption-atmospheric pressure chemical ionization mass spectrometry for the analysis of peptides from aqueous solutions [J].
Coon, JJ ;
Harrison, WW .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5600-5605
[4]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[5]   Analytical performance of a venturi device integrated into an electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer for analysis of nucleic acids [J].
Hawkridge, AM ;
Zhou, L ;
Lee, ML ;
Muddiman, DC .
ANALYTICAL CHEMISTRY, 2004, 76 (14) :4118-4122
[6]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION [J].
HENRY, KD ;
WILLIAMS, ER ;
WANG, BH ;
MCLAFFERTY, FW ;
SHABANOWITZ, J ;
HUNT, DF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9075-9078
[7]   Direct protein detection from biological media through electrospray-assisted laser desorption ionization/mass spectrometry [J].
Huang, MZ ;
Hsu, HJ ;
Lee, LY ;
Jeng, JY ;
Shiea, JT .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (05) :1107-1116
[8]   Analysis of the low molecular weight fraction of serum by LC-dual ESI-FT-ICR mass spectrometry: Precision of retention time, mass, and ion abundance [J].
Johnson, KL ;
Mason, CJ ;
Muddiman, DC ;
Eckel, JE .
ANALYTICAL CHEMISTRY, 2004, 76 (17) :5097-5103
[9]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[10]   Top-down proteomics [J].
Kelleher, NL .
ANALYTICAL CHEMISTRY, 2004, 76 (11) :196A-203A