Validity of a multi-sensor armband in estimating rest and exercise energy expenditure

被引:250
作者
Fruin, ML [1 ]
Rankin, JW [1 ]
机构
[1] Virginia Tech, Dept Human Nutr Foods & Exercise, Blacksburg, VA 24061 USA
关键词
SenseWear(TM) Armband; physical activity; caloric expenditure; activity monitoring; motion sensors;
D O I
10.1249/01.MSS.0000128144.91337.38
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: To examine the reliability and validity of the SWA during rest and exercise compared with indirect calorimetry (IC). Methods: EE was assessed with SWA and IC in 13 males. during two resting and one cycle ergometry (40 min at 60% VO2peak) sessions. In a second experiment, 20 adults walked on a treadmill for 30 min at three intensities (80.5 m(.)min(-1), 0% grade; 107.3 m(.)min(-1), 0% grade; 107.3 m-min(-1), 5% grade) while IC and SWA measured EE. Results: At rest, no significant differences were found between EE measurements from the SWA (1.3 +/- 0.1 kcal(.)min(-1)) and IC (1.3 +/- 0.1 kcal(.)min(-1)), and the two methods were highly correlated (r = 0.76; P < 0.004). The SWA EE estimation was reliable when comparing the two resting visits (r = 0.93; P < 0.001). For the ergometer protocol, no significant differences were found between the SWA and IC measurements of EE early, mid, or late in exercise or for the total bout, although the measurements were poorly correlated (r = 0.03-0.12). The SWA EE estimate of walking increased with treadmill speed but not with incline. The SWA significantly overestimated (13-27%) the EE of walking with no grade (P < 0.02) and significantly underestimated (22%) EE on the 5% grade (P < 0.002). The SWA estimation of EE correlated moderately with IC (r = 0.47-0.69). Conclusion: The SWA provided valid and reliable estimates of EE at rest and generated similar mean estimates of EE as IC on the ergometer; however, individual error was large. The SWA overestimated the EE of flat walking and underestimated inclined walking EE.
引用
收藏
页码:1063 / 1069
页数:7
相关论文
共 21 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Field evaluation of energy expenditure in women using Tritrac accelerometers [J].
Campbell, KL ;
Crocker, PRE ;
McKenzie, DC .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (10) :1667-1674
[3]   Improving energy expenditure estimation by using a triaxial accelerometer [J].
Chen, KY ;
Sun, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) :2112-2122
[4]   Predictors of weight change in men: Results from The Health Professionals Follow-Up Study [J].
Coakley, EH ;
Rimm, EB ;
Colditz, G ;
Kawachi, I ;
Willett, W .
INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (02) :89-96
[5]   Comparison of energy expenditure estimates from doubly labeled water, a physical activity questionnaire, and physical activity records [J].
Conway, JM ;
Seale, JL ;
Jacobs, DR ;
Irwin, ML ;
Ainsworth, BE .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (03) :519-525
[6]   Prevalence and trends in obesity among US adults, 1999-2000 [J].
Flegal, KM ;
Carroll, MD ;
Ogden, CL ;
Johnson, CL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (14) :1723-1727
[7]   GENERALIZED EQUATIONS FOR PREDICTING BODY DENSITY OF MEN [J].
JACKSON, AS ;
POLLOCK, ML .
BRITISH JOURNAL OF NUTRITION, 1978, 40 (03) :497-504
[8]  
JACKSON AS, 1980, MED SCI SPORT EXER, V12, P175
[9]   The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure [J].
Jakicic, JM ;
Winters, C ;
Lagally, K ;
Ho, J ;
Robertson, RJ ;
Wing, RR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (05) :747-754
[10]  
Leenders NYJM, 2001, MED SCI SPORT EXER, V33, P1233