Quantitative assessment of tissue perfusion using MDCT: Comparison of colorectal cancer and skeletal muscle measurement reproducibility

被引:62
作者
Goh, Vicky
Halligan, Steve
Hugill, Jo-Ann
Bartram, Clive I.
机构
[1] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
[2] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
关键词
cancer; colon; colorectal cancer; dynamic CT; MDCT; perfusion CT;
D O I
10.2214/AJR.05.0050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this study were to determine the reproducibility of quantitative colorectal cancer perfusion measurements using dynamic contrast-enhanced MDCT, and to compare this with measurements from skeletal muscle. SUBJECTS AND METHODS. Ten patients (mean age, 67 years; six men, four women) with histologically proven colorectal cancer were examined prospectively using 4-MDCT. Perfusion studies (cine mode; 4 x 5 turn collimation; 1 acquisition/s; 65 seconds total) were performed through the tumor epicenter after IV bolus contrast administration (iopamidol 340, 100 mL; 5 mL/s) and repeated within 48 hours. Quantitative values for blood volume, blood flow, mean transit time, and permeability were determined using commercial software. Two regions of interest were studied on the axial image: one within the tumor and another within the left gluteal muscle. Measurement reproducibility was assessed using Bland-Altman statistics. RESULTS. For the tumor, the mean difference (95% limits of agreement) was -0.04 mL/100 g tissue (-2.50, 2.42); 8.80 (-50.5, 68.0) mL/100 g tissue/min; -0.99 (-8.19, 6.20) seconds; and 1.20 (-5.42, 7.83) mL/100 g tissue/min for blood volume, blood flow, mean transit time, and permeability, respectively. For muscle, the mean difference (95% limits of agreement) was 0.02 (-1.40, 1.43), 6.60 (-11.2, 24.3), -3.76 (-16.87, 9.35), and 1.30 (-4.68, 7.28), respectively. CONCLUSION. Quantitative perfusion measurements are reproducible. Measurements from tumor are less variable than from skeletal muscle.
引用
收藏
页码:164 / 169
页数:6
相关论文
共 22 条
[1]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Bland M, 2003, INTRO MED STAT, P268
[4]  
Cenic A, 1999, AM J NEURORADIOL, V20, P63
[5]  
Cenic A, 2000, AM J NEURORADIOL, V21, P462
[6]  
Fiorella D, 2004, AM J NEURORADIOL, V25, P97
[7]   Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis [J].
Galbraith, SM ;
Lodge, MA ;
Taylor, NJ ;
Rustin, GJS ;
Bentzen, S ;
Stirling, JJ ;
Padhani, AR .
NMR IN BIOMEDICINE, 2002, 15 (02) :132-142
[8]  
GANONG WF, 1987, REV MED PHYSL, P493
[9]   Reproducibility of quantitative CT perfusion imaging [J].
Gillard, JH ;
Antoun, NM ;
Burnet, NG ;
Pickard, JD .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882) :552-555
[10]   Quantitative assessment of colorectal cancer perfusion using MDCT: inter- and intraobserver agreement [J].
Goh, V ;
Halligan, S ;
Hugill, JA ;
Bassett, P ;
Bartram, CI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) :225-231