Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding

被引:126
作者
Kim, Dong Sung
Lee, Se Hwan
Ahn, Chong H.
Lee, Jae Y.
Kwon, Tai Hun
机构
[1] Pohang Univ Sci & Technol, Dept Mech Engn, Pohang 790784, Kyungbuk, South Korea
[2] Pohang Univ Sci & Technol, Res Ctr Micro Mech Syst, Pohang 790784, Kyungbuk, South Korea
[3] Univ Cincinnati, Dept Elect & Comp Engn & Comp Sci, Cincinnati, OH 45221 USA
[4] Ohio State Univ, Coll Med, Cincinnati, OH 45221 USA
关键词
D O I
10.1039/b516495h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 mu l of the whole sample bloods, by means of the fabricated biochip within 3 min.
引用
收藏
页码:794 / 802
页数:9
相关论文
共 14 条
[1]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[2]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[3]  
FUNG YC, 1981, BIOMECHANICS MECH PR
[4]  
HAN KS, 1999, TRANSFUSION MED
[5]  
KIM D, UNPUB
[6]   A serpentine laminating micromixer combining splitting/recombination and advection [J].
Kim, DS ;
Lee, SH ;
Kwon, TH ;
Ahn, CH .
LAB ON A CHIP, 2005, 5 (07) :739-747
[7]   A barrier embedded Kenics micromixer [J].
Kim, DS ;
Lee, IH ;
Kwon, TH ;
Cho, DW .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (10) :1294-1301
[8]   Micro-channel filling flow considering surface tension effect [J].
Kim, DS ;
Lee, KC ;
Kwon, TH ;
Lee, SS .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (03) :236-246
[9]  
KIM DS, 2005, P MICR TOT AN SYST 2, P684
[10]   Evaluation of the gel system for ABO grouping and D typing [J].
Langston, MM ;
Procter, JL ;
Cipolone, KM ;
Stroncek, DF .
TRANSFUSION, 1999, 39 (03) :300-305