Large volume stacking using an EOF pump in NACE-MS

被引:21
作者
Kim, Jihye [1 ]
Chun, Man-Seog [2 ]
Choi, Kihwan [1 ]
Chung, Doo Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Chem, Seoul 151747, South Korea
[2] Korea Sci Acad, Pusan, South Korea
关键词
CE; ESI-MS; Large volume stacking using an EOF pump; NACE; CAPILLARY-ZONE-ELECTROPHORESIS; IONIZATION-MASS-SPECTROMETRY; SAMPLE STACKING; ELECTROOSMOTIC FLOW; NONAQUEOUS MEDIA; ESI-MS; ONLINE; INTERFACE; PH; ANIONS;
D O I
10.1002/elps.200800396
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Large volume stacking using an EOF pump (LVSEP) is realized for CE with ESI-MS. In LVSEP of anions, the adverse effects of a long sample matrix plug were overcome by pumping the plug out of the separation capillary to the inlet vial using the EOF under a potential of reverse polarity. Therefore, it was necessary to supply a backup run buffer from the outlet end of the capillary, which was not trivial in most ESI-MS configurations. We solved this difficulty simply by placing a vial supplying a backup run buffer during the matrix removal and sample stacking process. in addition, methanol was used as the run buffer solvent enabling a bare fused-silica capillary to meet the requirement of suppressed EOF. This LVSEP CE/ESI-MS has been successfully applied to six anionic analytes, achieving 400-fold enrichment in the detection sensitivity by using a conventional sheath liquid CE/ESI-MS interface without any physical modification.
引用
收藏
页码:1046 / 1051
页数:6
相关论文
共 49 条
[1]   Sample stacking capillary electrophoresis with ICP-(Q) MS detection for Cd, Cu and Zn speciation in fish liver metallothioneins [J].
Alvarez-Llamas, G ;
de la Campa, MDF ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :460-466
[2]  
Baryla NE, 2001, ELECTROPHORESIS, V22, P52, DOI 10.1002/1522-2683(200101)22:1<52::AID-ELPS52>3.0.CO
[3]  
2-Z
[4]  
BJONSDOTTIR I, 1998, ELECTROPHORESIS, V19, P2179
[5]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[6]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[7]   Overview on advances in capillary electrophoresis-mass spectrometry of carbohydrates: A tabulated review [J].
Campa, Cristiana ;
Coslovi, Anna ;
Flamigni, Anna ;
Rossi, Marco .
ELECTROPHORESIS, 2006, 27 (11) :2027-2050
[8]   Sensitivity enhancement in capillary electrophoresis-inductively coupled plasma-mass spectrometry for metal/protein interactions analysis by using large volume stacking with polarity switching [J].
Chamoun, J ;
Hagège, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (10) :1030-1034
[9]   Capillary isoelectric focusing-based multidimensional concentration/separation platform for proteome analysis [J].
Chen, JZ ;
Balgley, BM ;
DeVoe, DL ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3145-3152
[10]   A low-flow CE/electrospray ionization MS interface for capillary zone electrophoresis, large-volume sample stacking, and micellar electrokinetic chromatography [J].
Chen, YR ;
Tseng, MC ;
Chang, YZ ;
Her, GR .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :503-508