Guidelines for visualization of cutaneous blood flow by laser Doppler perfusion imaging -: A report from the Standardization Group of the European Society of Contact Dermatitis based upon the HIRELADO European community project

被引:73
作者
Fullerton, A
Stücker, M
Wilhelm, KP
Wårdell, K
Anderson, C
Fischer, T
Nilsson, GE
Serup, J
机构
[1] Leo Pharmaceut Prod Ltd, Dept Dermatol Res, DK-2750 Ballerup, Denmark
[2] Ruhr Univ Bochum, Dept Dermatol, D-44791 Bochum, Germany
[3] proDERM Inst Appl Derm Res GmbH, D-22869 Schenenfeld Hamburg, Germany
[4] Linkoping Univ, Dept Biomed Engn, SE-58185 Linkoping, Sweden
[5] Linkoping Univ Hosp, Dept Dermatol, S-58185 Linkoping, Sweden
[6] Natl Inst Working Life, S-17184 Solna, Sweden
关键词
bioengineering methods; cutaneous blood flow; laser Doppler perfusion imaging; microcirculation; measurement guidelines;
D O I
10.1034/j.1600-0536.2002.460301.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
This report reviews how to set up a laser Doppler perfusion imaging system intended for visualization of skin blood perfusion, capture images and evaluate the results obtained. A brief summary of related papers published in the literature within the areas of skin irritant and allergy patch testing, microdialysis and skin tumour circulation is presented, as well as early applications within other fields such as diabetology, wound healing and microvascular research.
引用
收藏
页码:129 / 140
页数:12
相关论文
共 55 条
  • [1] REPRODUCIBLE MEASUREMENTS TO QUANTIFY CUTANEOUS INVOLVEMENT IN SCLERODERMA
    AGHASSI, D
    MONOSON, T
    BRAVERMAN, I
    [J]. ARCHIVES OF DERMATOLOGY, 1995, 131 (10) : 1160 - 1166
  • [2] CHANGES IN SKIN CIRCULATION AFTER INSERTION OF A MICRODIALYSIS PROBE VISUALIZED BY LASER-DOPPLER PERFUSION IMAGING
    ANDERSON, C
    ANDERSSON, T
    WARDELL, K
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1994, 102 (05) : 807 - 811
  • [3] THE OPTICS OF HUMAN-SKIN
    ANDERSON, RR
    PARRISH, JA
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) : 13 - 19
  • [4] ANDERSSON T, 1995, ACTA DERM-VENEREOL, V75, P343
  • [5] PERFUSION IMAGING OF SKIN ISLAND FLAP BLOOD-FLOW BY A SCANNING LASER-DOPPLER TECHNIQUE
    ARNOLD, F
    HE, CF
    JIA, CY
    CHERRY, GW
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (05): : 280 - 287
  • [6] Differences in foot and forearm skin microcirculation in diabetic patients with and without neuropathy
    Arora, S
    Smakowski, P
    Frykberg, RG
    Simeone, LR
    Freeman, R
    LoGerfo, FW
    Veves, A
    [J]. DIABETES CARE, 1998, 21 (08) : 1339 - 1344
  • [7] AUER T, 1994, ACTA DERM-VENEREOL, V74, P30
  • [8] GUIDELINES FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY - A REPORT FROM THE STANDARDIZATION GROUP OF THE EUROPEAN-SOCIETY-OF-CONTACT-DERMATITIS
    BIRCHER, A
    DEBOER, EM
    AGNER, T
    WAHLBERG, JE
    SERUP, J
    [J]. CONTACT DERMATITIS, 1994, 30 (02) : 65 - 72
  • [9] Objective assessment of nickel sulfate patch test reactions with laser Doppler perfusion imaging
    Bjarnason, B
    Fischer, T
    [J]. CONTACT DERMATITIS, 1998, 39 (03) : 112 - 118
  • [10] Assessment of budesonide patch tests
    Bjarnason, B
    Flosadóttir, E
    Fischer, T
    [J]. CONTACT DERMATITIS, 1999, 41 (04) : 211 - 217