Humidification difficulties in two tracheostomized children

被引:5
作者
Edwards, EA [1 ]
Byrnes, CA [1 ]
机构
[1] Univ Auckland, Dept Paediat, Starship Hosp, Auckland, New Zealand
关键词
airway; tracheostomy; humidification; paediatrics;
D O I
10.1177/0310057X9902700618
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Effective humidification Is sometimes difficult to achieve in children when normal mechanisms are by passed by having a tracheostomy in situ. The humidification options available in the paediatric population are heat and moisture exchangers (HMEs) and heated humidifiers, both of which are reviewed and discussed. In some circumstances the humidification achieved with HMEs is inadequate. We outline the hospital and subsequent home management of two infants, both with tracheostomies in situ, who unsuccessfully trialed HMEs and subsequently achieved effective humidification with heated humidifiers. We propose that heated humidifiers would help more tracheostomized infants who are suffering from similar problems.
引用
收藏
页码:656 / 658
页数:3
相关论文
共 13 条
[11]   Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices [J].
Villafane, MC ;
Cinnella, G ;
Lofaso, F ;
Isabey, D ;
Harf, A ;
Lemaire, F ;
Brochard, L .
ANESTHESIOLOGY, 1996, 85 (06) :1341-1349
[12]  
Wilkes A R, 1998, Respir Care Clin N Am, V4, P261
[13]   Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa [J].
Williams, R ;
Rankin, N ;
Smith, T ;
Galler, D ;
Seakins, P .
CRITICAL CARE MEDICINE, 1996, 24 (11) :1920-1929