Characterization of an inductively coupled plasma with xylene solutions introduced as monodisperse aerosols

被引:19
作者
Lazar, AC [1 ]
Farnsworth, PB [1 ]
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM & BIOCHEM,PROVO,UT 84602
关键词
D O I
10.1021/ac970269+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The optimum operating parameters of the inductively coupled plasma (ICP) with organic solvents are different from those with aqueous solutions. With organic solvents, the ICP is operated at higher power to overcome plasma cooling due to the organic solvent, and aerosol desolvation is necessary in order to reduce solvent load into the plasma. The monodisperse dried microparticulate injector (MDMI) offers the possibility of controlling solvent load by controlling the frequency with which droplets are introduced into the plasma. A test solution that contained 0.5 mg/L Ba in xylene was used to study the influence of MDMI operating parameters on the behavior of the ICP with an organic solvent. The spatial and temporal distribution of the solvent in the ICP was determined for different droplet production frequencies and MDMI oven temperatures, and the optimum operating conditions were established. The best detection limit for Ba in xylene was 1.5 ng/mL, or 0.16 pg (in 200 droplets).
引用
收藏
页码:3921 / 3929
页数:9
相关论文
共 19 条
[1]  
[Anonymous], APPL INDUCTIVELY COU
[2]   CHARACTERIZATION AND OPTIMIZATION OF A DIRECT INJECTION NEBULIZER FOR INTRODUCTION OF ORGANIC-SOLVENTS AND VOLATILE ANALYTE SPECIES INTO AN INDUCTIVELY COUPLED PLASMA [J].
AVERY, TW ;
CHAKRABARTY, C ;
THOMPSON, JJ .
APPLIED SPECTROSCOPY, 1990, 44 (10) :1690-1698
[3]  
Boorn A. W., 1987, INDUCTIVELY COUPLE 2, P151
[4]   EFFECTS OF ORGANIC-SOLVENTS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BOORN, AW ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1402-1410
[5]   EVAPORATION CHARACTERISTICS OF ORGANIC-SOLVENT AEROSOLS USED IN ANALYTICAL ATOMIC SPECTROMETRY [J].
BOORN, AW ;
CRESSER, MS ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (11-1) :823-832
[6]   MODIFICATION AND OPTIMIZATION OF A 50 MHZ INDUCTIVELY COUPLED ARGON PLASMA WITH SPECIAL REFERENCE TO ANALYSES USING ORGANIC-SOLVENTS [J].
BOUMANS, PWJM ;
LUXSTEINER, MC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (02) :97-126
[7]   Time resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction [J].
Dziewatkoski, MP ;
Daniels, LB ;
Olesik, JW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1101-1109
[8]   MONODISPERSE DRIED MICROPARTICULATE INJECTOR FOR ANALYTICAL INSTRUMENTATION [J].
FRENCH, JB ;
ETKIN, B ;
JONG, R .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :685-691
[9]   Investigation of the analytical performance of an MDMI-ICP-AES system [J].
Lazar, AC ;
Farnsworth, PB .
APPLIED SPECTROSCOPY, 1997, 51 (05) :617-624
[10]   EXPERIMENTAL CONTROL OF THE SOLVENT LOAD OF INDUCTIVELY COUPLED ARGON PLASMAS AND EFFECTS OF THE CHLOROFORM PLASMA LOAD ON THEIR ANALYTICAL PERFORMANCE [J].
MAESSEN, FJMJ ;
KREUNING, G ;
BALKE, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (1-2) :3-25