Novel bioactive materials have been prepared by coating violet resorbable Vicryl(R) sutures with a bioactive glass powder derived from a co-precipitation method. Two techniques have been chosen for the composite preparation: pressing the sutures in a bed of glass powder and slurry-dipping of sutures in liquid suspensions of bioactive glass powders. The uniformity and thickness of the coatings obtained by the two methods were compared. The bioactivity of the sutures with and without bioactive glass coating was tested by soaking in an inorganic acellular simulated body fluid (SBF). The composite sutures were characterised by XRD, SEM and FTIR analyses before and after soaking in SBF solution to assess the formation of hydroxyapatite on their surfaces, which is a qualitative measure of their bioactivity. The possible use of bioactive sutures to produce tissue engineering scaffolds and as reinforcement of resorbable calcium phosphates is discussed. (C) 2004 Kluwer Academic Publishers.
引用
收藏
页码:893 / 899
页数:7
相关论文
共 27 条
[11]  
Kokubo T., 1991, BIOCERAMICS P 4 INT, P113, DOI DOI 10.1016/B978-0-7506-0269-3.50020-7
[12]   Strength retention properties of self-reinforced poly L-lactide (SR-PLLA) sutures compared with polyglyconate (MaxonR) and polydioxanone (PDS) sutures.: An in vitro study [J].
Mäkelä, P ;
Pohjonen, T ;
Törmälä, P ;
Waris, T ;
Ashammakhi, N .
BIOMATERIALS, 2002, 23 (12) :2587-2592
[13]   THE INVIVO AND INVITRO DEGRADATION OF POLY(GLYCOLIC ACID) SUTURE MATERIAL AS A FUNCTION OF APPLIED STRAIN [J].
MILLER, ND ;
WILLIAMS, DF .
BIOMATERIALS, 1984, 5 (06) :365-368
[14]   Stabilized polyglycolic acid fibre based tubes for tissue engineering [J].
Mooney, DT ;
Mazzoni, CL ;
Breuer, C ;
McNamara, K ;
Hern, D ;
Vacanti, JP ;
Langer, R .
BIOMATERIALS, 1996, 17 (02) :115-124
[15]   Comparison of in vivo dissolution processes in hydroxyapatite and silicon-substituted hydroxyapatite bioceramics [J].
Porter, AE ;
Patel, N ;
Skepper, JN ;
Best, SM ;
Bonfield, W .
BIOMATERIALS, 2003, 24 (25) :4609-4620
[16]   Development and in vitro characterisation of novel bioresorbable and bioactive composite materials based on polylactide foams and Bioglass® for tissue engineering applications [J].
Roether, JA ;
Boccaccini, AR ;
Hench, LL ;
Maquet, V ;
Gautier, S ;
Jérôme, R .
BIOMATERIALS, 2002, 23 (18) :3871-3878
[17]   In vitro dissolution of melt-derived 45S5 and sol-gel derived 58S bioactive glasses [J].
Sepulveda, P ;
Jones, JR ;
Hench, LL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (02) :301-311
[18]   Mechanical properties of biodegradable polymer sutures coated with bioactive glass [J].
Stamboulis, A ;
Hench, LL ;
Boccaccini, AR .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (09) :843-848
[19]   Bioresorbable polymers:: Their potential as scaffolds for Bioglass® composites [J].
Stamboulis, A ;
Hench, LL .
BIOCERAMICS, 2000, 192-1 :729-732
[20]  
Stamboulis AG, 2002, ADV ENG MATER, V4, P105, DOI 10.1002/1527-2648(200203)4:3<105::AID-ADEM105>3.3.CO