Lead-selective fluorescent optode membrane based on 3,3′,5,5′-tetramethyl-N-(9-anthrylmethyl)benzidine

被引:42
作者
Chan, WH
Yang, RH
Mo, T
Wang, KM
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, Changsha 410082, Peoples R China
关键词
fluorescent sensor; PVC membrane; ion-exchange; lead; TMANB;
D O I
10.1016/S0003-2670(02)00203-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new proton-selective fluorescing indicator, 3,3',5,5'-tetramethyl-N-(9-anthrylmethyl)benzidine (TMANB) has been synthesized and applied in an optode membrane for the determination of lead ion that works on the basis of a cation-exchange mechanism. When embedded in a plasticized poly(vinyl chloride) (PVC) membrane containing lead ionophore (tert-butylcalix[4] arene-tetrakis(N,N-dimethylthioacetamide)) and a lipophilic anionic site [potassium tetrakis(4-chlorophenyl)borate], TMANB shows a significant fluorescence signal change on exposure to aqueous HCl solution containing lead ion, which exhibits the theoretically expected fluorescence response to lead ion concentration. The selectivity, response time, reproducibility and reversibility, and lifetime of the optode membrane were discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 46 条
[11]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[12]   Novel mercury (II) ion-selective polymeric membrane sensor based on ethyl-2-benzoyl-2-phenylcarbamoyl acetate [J].
Hassan, SSM ;
Saleh, MB ;
Gaber, AAA ;
Mekheimer, RAH ;
Kream, NAA .
TALANTA, 2000, 53 (02) :285-293
[13]   ENANTIOSELECTIVE OPTODES [J].
HE, HR ;
URAY, G ;
WOLFBEIS, OS .
ANALYTICA CHIMICA ACTA, 1991, 246 (02) :251-257
[14]   A THIAMINE-SELECTIVE OPTICAL SENSOR BASED ON MOLECULAR RECOGNITION [J].
HE, HR ;
URAY, G ;
WOLFBEIS, OS .
ANALYTICAL LETTERS, 1992, 25 (03) :405-414
[15]   NOVEL TYPE OF ION-SELECTIVE FLUOROSENSOR BASED ON THE INNER FILTER EFFECT - AN OPTRODE FOR POTASSIUM [J].
HE, HR ;
LI, H ;
MOHR, G ;
KOVACS, B ;
WERNER, T ;
WOLFBEIS, OS .
ANALYTICAL CHEMISTRY, 1993, 65 (02) :123-127
[16]   SILVER ION-SELECTIVE OPTODES BASED ON NOVEL THIA ETHER COMPOUNDS [J].
HISAMOTO, H ;
NAKAGAWA, E ;
NAGATSUKA, K ;
ABE, Y ;
SATO, S ;
SISWANTA, D ;
SUZUKI, K .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1315-1321
[17]   FLOW-THROUGH TYPE CALCIUM-ION SELECTIVE OPTODES BASED ON NOVEL NEUTRAL IONOPHORES AND A LIPOPHILIC ANIONIC DYE [J].
HISAMOTO, H ;
WATANABE, K ;
NAKAGAWA, E ;
SISWANTA, D ;
SHICHI, Y ;
SUZUKI, K .
ANALYTICA CHIMICA ACTA, 1994, 299 (02) :179-187
[18]   ION-SELECTIVE OPTRODE USING HEXADECYL-ACRIDINE ORANGE ATTACHED ON POLY(VINYL CHLORIDE) MEMBRANE [J].
KAWABATA, Y ;
KAMICHIKA, T ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :2054-2055
[19]  
Kharitonov AB, 1997, J ANAL CHEM+, V52, P466
[20]   Micrometer-sized lithium ion-selective microoptodes based on a "tailed" neutral ionophore and a fluorescent anionic dye [J].
Kurihara, K ;
Ohtsu, M ;
Yoshida, T ;
Abe, T ;
Hisamoto, H ;
Suzuki, K .
ANALYTICA CHIMICA ACTA, 2001, 426 (01) :11-18