Three-dimensional reconstruction of curves from pairs of projection views in the presence of error .1. Algorithms

被引:22
作者
Bullitt, E
Liu, A
Pizer, SM
机构
[1] UNIV N CAROLINA, DEPT COMP SCI, CHAPEL HILL, NC 27599 USA
[2] UNIV N CAROLINA, DEPT BIOMED ENGN, CHAPEL HILL, NC 27599 USA
[3] UNIV N CAROLINA, DEPT RADIOL, CHAPEL HILL, NC 27599 USA
[4] UNIV N CAROLINA, DEPT RADIAT ONCOL, CHAPEL HILL, NC 27599 USA
关键词
angiography; intracerebral vessels; few-view reconstruction; 3D curve; vascular reconstruction;
D O I
10.1118/1.597952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have previously described an approach to 3D intracerebral vascular reconstruction that uses an MRA as a reconstruction base. Additional vessels seen only by angiography are added by segmenting 2D curves from projection angiograms and reconstructing these curves into 3D, building upon the MRA. Intracerebral vascular reconstruction is difficult for at least two reasons. First, 2D curves must be associated on projection images even when the human eye cannot do so. Second, 3D curves must be reconstructed in the presence of errors such as misregistration, image distortion, and misdefinition of 2D curves. This paper is the first of two that address the specific issue of reconstruction of a 3D curve from a given pair of 2D curves in the presence of error. The method explicitly separates what can and cannot be determined from a pair of projection views. It is also capable of recognizing interruptions produced by viewplane errors, of continuing reconstruction beyond such interruptions, and of localizing and estimating the magnitude of the interruptions. These measurements can also be used to estimate the lengths of regional disparities between a pair of 2D curves, leading to a quantitative estimate of the capacity of a pair of 2D curves to combine to create a 3D object (match value). Match values can be used, in turn, as part of the strategy for automatically associating pairs of 2D curves. This paper provides methods for reconstructing a given pair of 2D curves into 3D in the presence of error and for calculating match values. Error analysis is given in the companion report. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1671 / 1678
页数:8
相关论文
共 33 条
  • [21] INTRACRANIAL VASCULAR-LESIONS - OPTIMIZATION AND CLINICAL-EVALUATION OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    MARCHAL, G
    BOSMANS, H
    VANFRAEYENHOVEN, L
    WILMS, G
    VANHECKE, P
    PLETS, C
    BAERT, AL
    [J]. RADIOLOGY, 1990, 175 (02) : 443 - 448
  • [22] CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION
    NAPEL, S
    MARKS, MP
    RUBIN, GD
    DAKE, MD
    MCDONNELL, CH
    SONG, SM
    ENZMANN, DR
    JEFFREY, RB
    [J]. RADIOLOGY, 1992, 185 (02) : 607 - 610
  • [23] PAPADOPOULO T, 1996, COMP VIS ECCU 1996 4, V2, P696
  • [24] PARKER DL, 1986, 3 DIMENSIONAL RECONS, P414
  • [25] TREATMENT OF ARTERIOVENOUS-MALFORMATIONS WITH STEREOTAXIC RADIOSURGERY EMPLOYING BOTH MAGNETIC-RESONANCE ANGIOGRAPHY AND STANDARD ANGIOGRAPHY AS A DATABASE
    PETEREIT, D
    MEHTA, M
    TURSKI, P
    LEVIN, A
    STROTHER, C
    MISTRETTA, C
    MACKIE, R
    GEHRING, M
    KUBSAD, S
    KINSELLA, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02): : 309 - 313
  • [26] POLLOCK BE, 1996, CONT NEUROSURG, V18, P1
  • [27] COMPUTER-AIDED TECHNIQUE FOR OVERLAYING CEREBRAL ANGIOGRAMS ONTO COMPUTED TOMOGRAMS - 1978 MEMORIAL AWARD PAPER
    RUBIN, JM
    SAYRE, RE
    [J]. INVESTIGATIVE RADIOLOGY, 1978, 13 (05) : 362 - 367
  • [28] Smets C., 1988, Pattern Recognition and Artificial Intelligence. Towards an Integration. Proceedings of an International Workshop, P425
  • [29] SMETS C, 1990, THESIS
  • [30] Vandermeulen D., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V593, P103, DOI 10.1117/12.952156