Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: Results of a long-term multicenter study

被引:206
作者
Carson, CC [1 ]
Mulcahy, JJ
Govier, FE
机构
[1] Univ N Carolina, Chapel Hill, NC 27514 USA
[2] Wishard Mem Hosp, Indianapolis, IN USA
[3] Mason Clin, Seattle, WA USA
关键词
penis; impotence; prostheses and implants; dysfunction; erectile; satisfaction; patient;
D O I
10.1016/S0022-5347(05)67364-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We performed a long-term multicenter study of the AMS 700CX double dagger 3-piece inflatable penile prosthesis, focusing on longevity, morbidity and patient satisfaction in men implanted up to 134 months with a median followup of 47.7 months. Materials and Methods: We performed a large scale retrospective multicenter study in 2 phases. Phase 1 was a medical record review of 372 men who underwent implantation with the AMS 700CX penile prosthesis from 1987 to 1996 by 7 frequent penile prosthesis implanters, Phase 2 included a structured telephone interview of 207 patients by a neutral observer. Results: For the 372 men in phase 1 mean device mechanical reliability plus or minus standard deviation was 92.1% +/- 3.3% affer 3 and 86.2% +/- 4.6% after 5 years. Patient age was 21 to 79 years (mean 57.6 +/- 11.0) at implantation. The etiology of erectile dysfunction was vascular in 27.7% of the cases, Peyronie's disease in 16.9%, diabetes mellitus in 12.9% and radical surgery in 11.6%. Of the men 55.6% received previous treatment for erectile dysfunction. Postoperative infection and device malfunction developed in 3.2% and 17.5% of the cases, respectively. Of the 207 men interviewed in phase 2, 86% still had an AMS 700CX penile prosthesis implanted, including 87.1% with erection suitable for coitus. Currently 79% of those with a device use it at least twice monthly and 88.2% would recommend an implant to a relative or friend. Conclusions: The AMS 700CX penile implant produced suitable erection and excellent patient satisfaction at long-term followup in the majority of men. Implant reliability is excellent and postoperative morbidity is low.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 24 条
[1]   Long-term mechanical reliability of AMS 700 series inflatable penile prostheses: Comparison of CX/CXM and Ultrex cylinders [J].
Daitch, JA ;
Angermeier, KW ;
Lakin, MM ;
Ingleright, BJ ;
Montague, DK .
JOURNAL OF UROLOGY, 1997, 158 (04) :1400-1402
[2]   Long-term mechanical reliability of multicomponent inflatable penile prosthesis: Comparison of device survival [J].
Dubocq, F ;
Tefilli, MV ;
Gheiler, EL ;
Li, HK ;
Dhabuwala, CB .
UROLOGY, 1998, 52 (02) :277-281
[3]   EXPERIENCE WITH INFLATABLE PENILE PROSTHESIS [J].
FISHMAN, IJ ;
SCOTT, FB ;
LIGHT, JK .
UROLOGY, 1984, 23 :86-92
[5]   Does surgical approach affect the incidence of inflatable penile prosthesis infection? [J].
Garber, BB ;
Marcus, SM .
UROLOGY, 1998, 52 (02) :291-293
[6]  
GERSTENBERGER DI, 1986, UROLOGY, V14, P583
[7]   Safety and efficacy outcome of mentor alpha-1 inflatable penile prosthesis implantation for impotence treatment [J].
Goldstein, I ;
Newman, L ;
Baum, N ;
Brooks, M ;
Chaikin, L ;
Goldberg, K ;
McBride, A ;
Krane, RJ .
JOURNAL OF UROLOGY, 1997, 157 (03) :833-839
[8]   Mechanical reliability, surgical complications, and patient and partner satisfaction of the modern three-piece inflatable penile prosthesis [J].
Govier, FE ;
Gibbons, RP ;
Correa, RJ ;
Pritchett, TR ;
Kramer-Levien, D .
UROLOGY, 1998, 52 (02) :282-286
[9]  
HABAL MB, 1984, ARCH SURG-CHICAGO, V119, P843
[10]   Intermediate term assessment of the reliability, function and patient satisfaction with the AMS700 Ultrex penile prosthesis [J].
Holloway, FB ;
Farah, RN .
JOURNAL OF UROLOGY, 1997, 157 (05) :1687-1691