Treatment of acute pulmonary embolism:: Local effects of three hydrodynamic thrombectomy devices in an ex vivo porcine model

被引:20
作者
Biederer, Juergen
Charalambous, Nikolas
Paulsen, Friedrich
Heller, Martin
Mueller-Huelsbeck, Stefan
机构
[1] Univ Halle Wittenberg, Dept Anat & Cell Biol, D-4010 Halle, Germany
[2] Univ Hosp Schleswig, Dept Diagnost Radiol, Holstein, Germany
关键词
hydrodynamic thrombectomy; rheolytic thrombectomy; percutaneous mechanical thrombectomy; experimental study; ex vivo model; pulmonary artery; embolism; lung explants;
D O I
10.1583/06-1862.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To report an ex vivo study on the local effects of hydrodynamic thrombectomy for the treatment of acute pulmonary embolism (off-label use). Methods: Three devices (6-F AngioJet Xpeedior and 6-F and 8-F Oasis) were used for hydrodynamic thrombectomy inside the arteries of 24 inflated and perfused porcine lung explants. Each system was used at multiple positions inside 4 intact and 4 embolized lungs in vessels measuring 2 to 4 mm, 4 to 6 mm, 6 to 8 mm, and 8 to 10 mm. Angiograms prior to, during, and after catheter positioning and system operation were used to detect arterial wall trauma and to measure local clot removal per 30-second cycle. A total of 21 vessel wall samples were subjected to scanning electron microscopy (SEM) to evaluate non-perforating lesions. Results: All systems were able to remove clot material. The average recanalized vessel length normalized to 30 seconds for vessel diameters of 2 to 4 and 8 to 10 mm, respectively, was 1.17 and 1.75 cm (AngioJet), 0.97 and 0.25 cm (6-F Oasis), and 2.2 and 1.05 cm (8-F Oasis). Perforations occurred during positioning of the 6-F Oasis (4/78 maneuvers) and 8-F Oasis (13/60), but not the AngioJet (0/89); perforations were also seen during system operation (AngioJet: 21/89 activations, 6-F Oasis: 4/78, and 8-F Oasis: 9/60; all lesions inside vessels <6 mm in diameter). SEM showed 35 lesions, 14 with perforation (contrast extravasation) and 21 without perforation (induced by the tip of the guidewire). Conclusion: The AngioJet was most efficient in clot removal, followed by the 8-F Oasis. The 6-F Oasis was least efficient, but had fewest complications. According to these experiments, the tested hydrodynamic thrombectomy devices may cause perforations in vessels <6 mm in diameter. Changes in catheter design to reduce system-specific complication rates or to improve the efficacy of clot removal are warranted.
引用
收藏
页码:549 / 560
页数:12
相关论文
共 37 条
[1]   Acute pulmonary embolectomy - A contemporary approach [J].
Aklog, L ;
Williams, CS ;
Byrne, JG ;
Goldhaber, SZ .
CIRCULATION, 2002, 105 (12) :1416-1419
[2]   A POPULATION-BASED PERSPECTIVE OF THE HOSPITAL INCIDENCE AND CASE-FATALITY RATES OF DEEP-VEIN THROMBOSIS AND PULMONARY-EMBOLISM - THE WORCESTER DVT STUDY [J].
ANDERSON, FA ;
WHEELER, HB ;
GOLDBERG, RJ ;
HOSMER, DW ;
PATWARDHAN, NA ;
JOVANOVIC, B ;
FORCIER, A ;
DALEN, JE .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (05) :933-938
[3]  
Ando M, 1996, Nihon Kyobu Geka Gakkai Zasshi, V44, P505
[4]   Syndromes of thrombosis and hypercoagulability - Congenital and acquired causes of thrombosis [J].
Bick, RL ;
Kaplan, H .
MEDICAL CLINICS OF NORTH AMERICA, 1998, 82 (03) :409-+
[5]  
Biederer J, 2003, J ENDOVASC THER, V10, P99, DOI 10.1583/1545-1550(2003)010<0099:SPADAT>2.0.CO
[6]  
2
[7]   Artificial thorax for MR imaging studies in porcine heart-lung preparations [J].
Biederer, J ;
Heller, M .
RADIOLOGY, 2003, 226 (01) :250-255
[8]   PERCUTANEOUS CATHETER FRAGMENTATION AND DISTAL DISPERSION OF PROXIMAL PULMONARY EMBOLUS [J].
BRADY, AJB ;
CRAKE, T ;
OAKLEY, CM .
LANCET, 1991, 338 (8776) :1186-1189
[9]  
Brenes Juan-Carlos, 2004, J Invasive Cardiol, V16, P42
[10]  
Cho K J, 2000, Semin Vasc Surg, V13, P221