摘要
Percentage depth doses from the surface to a depth of 30 cm have been measured for a number of square fields using 6 MV and 15 MV X-rays as part of the commissioning procedure for a commercially available MLC. Factors such as changing SSD, presence of a secondary blocking tray in the beam, and radiation transmission between the MLC leaves were investigated. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 11 条
[1]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[2]   THE ACCEPTABILITY OF A MULTILEAF COLLIMATOR AS A REPLACEMENT FOR CONVENTIONAL BLOCKS [J].
FERNANDEZ, EM ;
SHENTALL, GS ;
MAYLES, WPM ;
DEARNALEY, DP .
RADIOTHERAPY AND ONCOLOGY, 1995, 36 (01) :65-74
[3]   Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields [J].
Frazier, A ;
Du, M ;
Wong, J ;
Vicini, F ;
Taylor, R ;
Yu, C ;
Matter, R ;
Martinez, A ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1229-1238
[4]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[5]   MULTILEAF COLLIMATION VERSUS CONVENTIONAL SHIELDING BLOCKS - A TIME AND MOTION STUDY OF BEAM SHAPING IN RADIOTHERAPY [J].
HELYER, SJ ;
HEISIG, S .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :61-64
[6]  
HUQ M, 1994, MED PHYS, V22, P241
[7]   EFFECT OF VARIOUS ATOMIC NUMBER ABSORBERS ON SKIN DOSE FOR 10-MEV X-RAYS [J].
KHAN, FM ;
MOORE, VC ;
LEVITT, SH .
RADIOLOGY, 1973, 109 (01) :209-212
[8]   A quality assurance program for ancillary high technology devices on a dual-energy accelerator [J].
Klein, EE ;
Low, DA ;
Maag, D ;
Purdy, JA .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (01) :51-60
[9]   Clinical implementation of a commercial multileaf collimator: Dosimetry, networking, simulation, and quality assurance [J].
Klein, EE ;
Harms, WB ;
Low, DA ;
Willcut, V ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1195-1208
[10]   3-DIMENSIONAL TREATMENT PLANNING AND CONFORMAL RADIATION-THERAPY - PRELIMINARY EVALUATION [J].
PEREZ, CA ;
PURDY, JA ;
HARMS, W ;
GERBER, R ;
GRAHAM, MV ;
MATTHEWS, JW ;
BOSCH, W ;
DRZYMALA, R ;
EMAMI, B ;
FOX, S ;
KLEIN, E ;
LEE, HK ;
MICHALSKI, JM ;
SIMPSON, JR .
RADIOTHERAPY AND ONCOLOGY, 1995, 36 (01) :32-43