THE ACCEPTABILITY OF A MULTILEAF COLLIMATOR AS A REPLACEMENT FOR CONVENTIONAL BLOCKS

被引:28
作者
FERNANDEZ, EM [1 ]
SHENTALL, GS [1 ]
MAYLES, WPM [1 ]
DEARNALEY, DP [1 ]
机构
[1] ROYAL MARSDEN HOSP,NHS TRUST,DEPT RADIOTHERAPY,SUTTON SM2 5PT,SURREY,ENGLAND
关键词
MULTILEAF COLLIMATOR; BEAM BLOCK;
D O I
10.1016/0167-8140(95)01571-W
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A multileaf collimator (MLC) can be used as a replacement for conventional blocks as well as for conformal radiotherapy. This study has assessed the possibility of using a Philips MLC for 218 patients treated with conventionally blocked fields. It was found that MLC field shaping would have been appropriate for over 94% of such patients. The facility to treat large blocked fields has been found to be particularly useful. Use of the predefined shapes stored in the Regular Shape Library provided by Philips was evaluated and it was found that an appropriate shape was available in 52% of cases. The application of MLC fields to the treatment of different anatomical sites is discussed.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 16 条
[1]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[2]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[3]  
CHENG CW, 1989, MED PHYS, V16, P673
[4]   3-DIMENSIONAL PHOTON RADIOTHERAPY PLANNING FOR LARYNGEAL AND HYPOPHARYNGEAL CANCERS .2. CONFORMATION TREATMENT PLANNING USING A MULTILEAF COLLIMATOR [J].
ESIK, O ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W ;
NEMETH, G ;
LORENZ, WJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (04) :238-244
[5]  
FERNANDEZ EM, 1993, 2ND P ESTRO M PHYS C, P166
[6]   EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM [J].
GALVIN, JM ;
SMITH, AR ;
MOELLER, RD ;
GOODMAN, RL ;
POWLIS, WD ;
RUBENSTEIN, J ;
SOLIN, LJ ;
MICHAEL, B ;
NEEDHAM, M ;
HUNTZINGER, CJ ;
KLIGERMAN, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04) :789-801
[7]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[8]  
HELYER SA, 1994, BR J CANCER S22, V70, P32
[9]   THE DESIGN AND PERFORMANCE-CHARACTERISTICS OF A MULTILEAF COLLIMATOR [J].
JORDAN, TJ ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :231-251
[10]   A MONO ISOCENTRIC TECHNIQUE FOR BREAST AND REGIONAL NODAL THERAPY USING DUAL ASYMMETRIC JAWS [J].
KLEIN, EE ;
TAYLOR, M ;
MICHALETZLORENZ, M ;
ZOELLER, D ;
UMFLEET, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :753-760