Segmentation of two- and three-dimensional data from electron microscopy using eigenvector analysis

被引:50
作者
Frangakis, AS [1 ]
Hegerl, R [1 ]
机构
[1] Max Planck Inst Biochem, D-82152 Martinsried, Germany
关键词
D O I
10.1016/S1047-8477(02)00032-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An automatic image segmentation method is used to improve processing and visualization of data obtained by electron microscopy. Exploiting affinity criteria between pixels, e.g., proximity and gray level similarity, in conjunction with an eigenvector analysis, the image is subdivided into areas which correspond to objects or meaningful regions. Extending a proposal by Shi and Malik (1997, Proceedings of the IEEE conference on Computer Vision and Pattern Recognition, pp. 731-737) the approach was adapted to the field of electron microscopy, especially to three-dimensional application as needed by electron tomography. Theory, implementation, parameter setting, and results obtained with a variety of data are presented and discussed. The method turns out to be a powerful tool for visualization with the potential for further improvement by developing and tuning new affinity. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 11 条
  • [1] Electron tomography of molecules and cells
    Baumeister, W
    Grimm, R
    Walz, J
    [J]. TRENDS IN CELL BIOLOGY, 1999, 9 (02) : 81 - 85
  • [2] FhuA-mediated phage genome transfer into liposomes:: A cryo-electron tomography study
    Böhm, J
    Lambert, O
    Frangakis, AS
    Letellier, L
    Baumeister, W
    Rigaud, JL
    [J]. CURRENT BIOLOGY, 2001, 11 (15) : 1168 - 1175
  • [3] Leginon: An automated system for acquisition of images from vitreous ice specimens
    Carragher, B
    Kisseberth, N
    Kriegman, D
    Milligan, RA
    Potter, CS
    Pulokas, J
    Reilein, A
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2000, 132 (01) : 33 - 45
  • [4] Wavelet transform filtering and nonlinear anisotropic diffusion assessed for signal reconstruction performance on multidimensional biomedical data
    Frangakis, AS
    Stoschek, A
    Hegerl, R
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) : 213 - 222
  • [5] Noise reduction in electron tomographic reconstructions using nonlinear anisotropic diffusion
    Frangakis, AS
    Hegerl, R
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2001, 135 (03) : 239 - 250
  • [6] Perspectives of molecular and cellular electron tomography
    Koster, AJ
    Grimm, R
    Typke, D
    Hegerl, R
    Stoschek, A
    Walz, J
    Baumeister, W
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 1997, 120 (03) : 276 - 308
  • [7] Russ J.C., 2016, The image processing handbook, Vseventh
  • [8] Sethian J.A, 1999, LEVEL SET METHODS FA
  • [9] Normalized cuts and image segmentation
    Shi, JB
    Malik, J
    [J]. 1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, : 731 - 737