Comparison of MR-thermography and planning calculations in phantoms

被引:31
作者
Gellermann, J.
Weihrauch, M.
Cho, C. H.
Wlodarczyk, W.
Faehling, H.
Felix, R.
Rudach, V.
Weiser, M.
Nadobny, J.
Wust, P.
机构
[1] Univ Med Berlin, Charite, Radiol Unit, D-13125 Berlin, Germany
[2] Univ Med Berlin, Charite, Clin Radiat Med, D-13353 Berlin, Germany
[3] Univ Med Berlin, Charite, Clin Radiotherapy, D-10098 Berlin, Germany
[4] Konrad Zuse Zentrum, Dept Numer Anal & Modeling, D-14195 Berlin, Germany
关键词
hyperthermia planning; magnetic resonance thermography; annular-phased array; phantom;
D O I
10.1118/1.2348761
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A systematic comparison of three-dimensional MR (magnetic resonance) thermography and planning calculations in phantoms for the hyperthermia (HT) SIGMA-Eye applicator. We performed 2 X 6 experiments in a homogeneous cylindrical and a heterogeneous elliptical phantom by adjusting 82 different patterns with different phase control inside an MR tomograph (Siemens Magnetom Symphony, 1.5 Tesla). For MR thermography, we employed the proton resonance frequency shift method with a drift correction based on silicon tubes. For the planning calculations, we used the finite-difference time-domain (FDTD) method and, in addition, modeled the antennas and the transforming network. We generated regions according to a segmentation of bones and tissue, and used an interpolation technique with a subgrid of 0.5 cm size at the interfaces. A Gauss-Newton solver has been developed to adapt phases and amplitudes. A qualitative agreement between the planning program and measurements was obtained, including a correct prediction of hot spot locations. The final deviation between planning and measurement is in the range of 2-3 W/kg, i.e., below 10%. Additional HT phase and amplitude adaptation, as well as position correction of the phantom in the SIGMA-Eye, further improve the results. HT phase corrections in the range of 30-40 degrees and HT amplitude corrections of +/- 20-30% are required for the best agreement. The deviation vertical bar MR-FDTD vertical bar, and the HT phase/amplitude corrections depend on the type of phantom, certain channel groups, pattern steering, and the positioning error. Appropriate agreement between three-dimensional specific absorption rate distributions measured by MR-thermography and planning calculations is achieved, if the correct position and adapted feed point parameters are considered. As long as feed-point parameters are uncertain (i.e., cannot be directly measured during therapy), a prospective planning will remain difficult. However, we can use the information of MR thermography to better predict the patterns in the future even without the knowledge of feed-point parameters. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3912 / 3920
页数:9
相关论文
共 37 条
[1]   A PERFECTLY MATCHED LAYER FOR THE ABSORPTION OF ELECTROMAGNETIC-WAVES [J].
BERENGER, JP .
JOURNAL OF COMPUTATIONAL PHYSICS, 1994, 114 (02) :185-200
[2]   Calibrated electro-optic E-field sensors for hyperthermia applications [J].
Berger, J ;
Petermann, K ;
Fähling, H ;
Wust, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :399-411
[3]   Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system [J].
Gellermann, J ;
Wlodarczyk, W ;
Feussner, A ;
Fähling, H ;
Nadobny, J ;
Hildebrandt, B ;
Felix, R ;
Wust, P .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2005, 21 (06) :497-513
[4]   Clinical evaluation and verification of the hyperthermia treatment planning system HyperPlan [J].
Gellermann, J ;
Wust, P ;
Stalling, D ;
Seebass, M ;
Nadobny, J ;
Beck, R ;
Hege, HC ;
Deuflhard, P ;
Felix, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04) :1145-1156
[5]   A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system:: Validation in a heterogeneous phantom [J].
Gellermann, J ;
Wlodarczyk, W ;
Ganter, H ;
Nadobny, J ;
Fähling, H ;
Seebass, M ;
Felix, R ;
Wust, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01) :267-277
[6]  
GELLERMANN J, 2006, IN PRESS CANCER
[7]  
GELLERMANN J, 2005, CANCER RES, V65, P1
[8]  
JUERGENS TG, 1992, IEEE T ANTENN PROPAG, V40, P357
[9]   FDTD analysis of dielectric resonators with curved surfaces [J].
Kaneda, N ;
Houshmand, B ;
Itoh, T .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1997, 45 (09) :1645-1649
[10]   Stability and accuracy of power and phase measurements of a VVM system designed for online quality control of the BSD-2000 (-3D) DHT system [J].
Lee, WM ;
Ameziane, A ;
Van den Biggelaar, AMC ;
Rietveld, PJM ;
Van Rhoon, GC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2003, 19 (01) :74-88