Stability and accuracy of power and phase measurements of a VVM system designed for online quality control of the BSD-2000 (-3D) DHT system

被引:10
作者
Lee, WM [1 ]
Ameziane, A [1 ]
Van den Biggelaar, AMC [1 ]
Rietveld, PJM [1 ]
Van Rhoon, GC [1 ]
机构
[1] Univ Hosp Rotterdam Daniel, Dept Radiat Oncol, Subdiv Hyperthermia, NL-3008 AE Rotterdam, Netherlands
关键词
hyperthermia; quality assurance; VVM-based power; phase measurements;
D O I
10.1080/02656730210166159
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Accurate control of power and phase is essential for the quality assurance of hyperthermia treatments. Hereto, an external measurement device was inserted, built around a Vector Voltmeter (VVM), in order to assess online the performance of the steering capability of the BSD-2000 and later the BSD-2000-3D system. This paper only concerns the power and phase calibration of the signal in the path between the power and phase detection probes of the BSD-system and power and phase measurement point of the VVM. The calibration is performed in the frequency range of 60 120 MHz using a network analyser with a frequency range of 0.01-500 MHz. More importantly, by repeating the calibration periodically over the last 3 years, the stability and accuracy of the power and phase measurements were determined using the VVM system. The results of the power calibration show that the VVM system, concerning its power and phase measurement, is stable in time. The variation of the power measured with the VVM system is less than 0.22 dB (5.2%) for the latest configuration of the BSD-2000-3D system. The variation of the VVM-based phase measurements of the latter configurations is 1.1degrees or less. From the results of the power and phase measurements in the BSD 2000 system reported in previous studies using other measurement systems, it follows that the uncertainties of the power and phase measurements with the currently proposed VVM system are small enough to assess accurately the performance of the BSD system concerning its steering capability.
引用
收藏
页码:74 / 88
页数:15
相关论文
共 13 条
[1]   An on-line phase measurement system for quality assurance of the BSD 2000. Part I: technical description of the measurement system [J].
Gromoll, C ;
Lamprecht, U ;
Hehr, T ;
Buchgeister, M ;
Bamberg, M .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2000, 16 (04) :355-363
[2]   Quality assurance for radiofrequency regional hyperthermia [J].
Hornsleth, SN ;
Frydendal, L ;
Mella, O ;
Dahl, O ;
Raskmark, P .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1997, 13 (02) :169-185
[3]   ESHO quality assurance guidelines for regional hyperthermia [J].
Lagendijk, JJW ;
Van Rhoon, GC ;
Hornsleth, SN ;
Wust, P ;
De Leeuw, ACC ;
Schneider, CJ ;
Van Dijk, JDP ;
Van der Zee, J ;
Van Heek-Romanowski, R ;
Rahman, SA ;
Gromoll, C .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1998, 14 (02) :125-133
[4]   An on-line phase measurement system for quality assurance of the BSD 2000. Part II: results of the phase measurement system [J].
Lamprecht, U ;
Gromoll, C ;
Hehr, T ;
Buchgeister, M ;
Bamberg, M .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2000, 16 (04) :365-373
[5]  
RIETVELD PJM, 2000, COMMUNICATION
[6]  
SCHNEIDER CJ, 1996, PRINCIPLES PRACTICE, P381
[7]  
TURNER PF, 1989, STRAHLENTHER ONKOL, V165, P738
[8]   Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumours:: a prospective, randomised, multicentre trial [J].
van der Zee, J ;
González, DG ;
van Rhoon, GC ;
van Dijk, JDP ;
van Putten, WLJ ;
Hart, AAM .
LANCET, 2000, 355 (9210) :1119-1125
[9]  
VANDERZEE J, 1993, FINAL REPORT STUDY F
[10]  
VANRHOON GC, 2001, SENSOR TECHNOLOGY 20, P119