An on-line phase measurement system for quality assurance of the BSD 2000. Part I: technical description of the measurement system

被引:5
作者
Gromoll, C [1 ]
Lamprecht, U
Hehr, T
Buchgeister, M
Bamberg, M
机构
[1] Univ Tubingen, Dept Radiotherapy, D-72074 Tubingen, Germany
[2] Univ Tubingen, Sect Med Phys, D-72074 Tubingen, Germany
[3] Hosp Kemperhof Koblenz, Sect Med Phys, Koblenz, Germany
关键词
regional hyperthermia; quality assurance; phase measurement;
D O I
10.1080/02656730050074113
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The hyperthermia system BSD 2000 with the ring applicator Sigma 60 utilizes the principle of a phase controlled group radiation source. The accuracy of the phase relationship between the four receiving HF signals is crucial for the position of the electric field inside the applicator. Therefore, essential significance falls to the phase control of the system. An automatic phase measuring technique has been developed to register immediately the phase position of the four channels of the BSD 2000 with respect to a reference signal. The system improves the ensurance of the technical safeguarding. In the first part of this work, the technical realization of the measurement system is described and first measurements with the system are given. In the second part, results with respect to the quality assurance of the BSD 2000 system are presented.
引用
收藏
页码:355 / 363
页数:9
相关论文
共 13 条
[1]  
*BSD, 2000, SIGM 60 APPL OP MAN, P31
[2]   VERIFICATION OF A HYPERTHERMIA MODEL METHOD USING MR THERMOMETRY [J].
CLEGG, ST ;
DAS, SK ;
ZHANG, Y ;
MACFALL, J ;
FULLAR, E ;
SAMULSKI, TV .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (03) :409-424
[3]  
GROMOLL C, 1997, STRAHLENTHER ONKOL, V173, P607
[4]  
GROMOLL C, 1995, STRAHLENTHER ONKOL, V171, P1
[5]   Quality assurance for radiofrequency regional hyperthermia [J].
Hornsleth, SN ;
Frydendal, L ;
Mella, O ;
Dahl, O ;
Raskmark, P .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1997, 13 (02) :169-185
[6]  
HORNSLETH SN, 1993, HYPERTHERMIA CLIN ON, P19
[7]  
HORNSLETH SN, 1995, ESHO 95 PROGRAMME BO, P47
[8]   ESHO quality assurance guidelines for regional hyperthermia [J].
Lagendijk, JJW ;
Van Rhoon, GC ;
Hornsleth, SN ;
Wust, P ;
De Leeuw, ACC ;
Schneider, CJ ;
Van Dijk, JDP ;
Van der Zee, J ;
Van Heek-Romanowski, R ;
Rahman, SA ;
Gromoll, C .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1998, 14 (02) :125-133
[9]  
LAMPRECHT U, 1999, IN PRESS INT J HYPER
[10]   EVALUATION OF THE SIGMA-60 APPLICATOR FOR REGIONAL HYPERTHERMIA IN TERMS OF SCATTERING PARAMETERS [J].
LEYBOVICH, LB ;
MYERSON, RJ ;
EMAMI, B ;
STRAUBE, WL .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (06) :917-935