An on-line phase measurement system for quality assurance of the BSD 2000. Part II: results of the phase measurement system

被引:5
作者
Lamprecht, U
Gromoll, C [1 ]
Hehr, T
Buchgeister, M
Bamberg, M
机构
[1] Univ Tubingen, Dept Radiotherapy & Oncol, D-72074 Tubingen, Germany
[2] Univ Tubingen, Sect Med Phys, D-72074 Tubingen, Germany
[3] Hosp Kemperhof Koblenz, Sect Med Phys, D-56065 Koblenz, Germany
关键词
regional hyperthermia; quality assurance; phase measurement;
D O I
10.1080/02656730050074122
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Phase constancy and accuracy are significant for regional hyperthermia with phased array radiofrequency hyperthermia systems. They are both necessary for a precise target steering in therapy. For the BSD 2000 system (BSD Medical Corp. Salt Lake City, Utah, USA), the phase values of all channels are checked with a self-developed automatic on-line phase measurement system. On different days the phases are measured under identical conditions, where the output paths are cut off with 50 Omega dummy loads to suppress the influence of the radiation conditions of the antennae on the measurement values. The results show how the phase values of the four channels change in the first 30 min and from day to day. During this time interval after the start the phases drop down by up to 15 degrees. For the time later changes are very slight and the differences from day to day are negligible. The phase shift that occurs in the first 30 min is as high as a change of the target point by 1 cm. Earlier switching on of the amplifiers prevents this shift occurring during the treatment. The measurement system provides a good tool for determination of phase accuracy and is easy to realize.
引用
收藏
页码:365 / 373
页数:9
相关论文
共 15 条
[1]   VERIFICATION OF A HYPERTHERMIA MODEL METHOD USING MR THERMOMETRY [J].
CLEGG, ST ;
DAS, SK ;
ZHANG, Y ;
MACFALL, J ;
FULLAR, E ;
SAMULSKI, TV .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (03) :409-424
[2]   An on-line phase measurement system for quality assurance of the BSD 2000. Part I: technical description of the measurement system [J].
Gromoll, C ;
Lamprecht, U ;
Hehr, T ;
Buchgeister, M ;
Bamberg, M .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2000, 16 (04) :355-363
[3]  
GROMOLL C, 1997, STRAHLENTHER ONKOL, V173, P607
[4]  
GROMOLL C, 1995, STRAHLENTHER ONKOL, V171, P1
[5]   Quality assurance for radiofrequency regional hyperthermia [J].
Hornsleth, SN ;
Frydendal, L ;
Mella, O ;
Dahl, O ;
Raskmark, P .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1997, 13 (02) :169-185
[6]  
HORNSLETH SN, 1993, HYPERTHERMIA CLIN ON, P19
[7]  
HORNSLETH SN, 1995, ESHO 95 PROGRAMME BO, P47
[8]   ESHO quality assurance guidelines for regional hyperthermia [J].
Lagendijk, JJW ;
Van Rhoon, GC ;
Hornsleth, SN ;
Wust, P ;
De Leeuw, ACC ;
Schneider, CJ ;
Van Dijk, JDP ;
Van der Zee, J ;
Van Heek-Romanowski, R ;
Rahman, SA ;
Gromoll, C .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1998, 14 (02) :125-133
[9]  
LAMPRECHT U, 1998, HYPERTHERMIA CLIN ON, P40
[10]   EVALUATION OF THE SIGMA-60 APPLICATOR FOR REGIONAL HYPERTHERMIA IN TERMS OF SCATTERING PARAMETERS [J].
LEYBOVICH, LB ;
MYERSON, RJ ;
EMAMI, B ;
STRAUBE, WL .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (06) :917-935