Spanish on Registry Implantable Cardioverter Defibrillator second official report of the Spanish Society of Cardiology Working Group on Implantable Cardioverter Defibrillators (2005)

被引:7
作者
Peinado, Rafael [1 ]
Torrecilla, Esteban G. [1 ]
Ormaetxe, Jose [1 ]
Alvarez, Miguel [1 ]
机构
[1] Soc Espanola Cardiol, Secc Electrofisiol & Arritmias, Grp Trabajo Desfibrilador Implantable, Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2006年 / 59卷 / 12期
关键词
defibrillator; registry; arrhythmia;
D O I
10.1157/13096579
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objective. We report the results for the Spanish Registry on Implantable Cardioverter Defibrillators (ICD) (year 2005), developed by the Working Group on ICD of the Spanish Society of Cardiology. Methods. Data were collected (prospectively in 77% of implants) by single page form questionnaires transmitted after the procedure to the Spanish Society of Cardiology. Participation was voluntary. Results. The number of implants sent to the Registry was 2050 and this represents 74.4% of the total ICDs implanted. The implantation rate per million was 46.5 and the estimated total implantation rate per million was 62.5. The proportion of first implants was 70.3%. The majority of patients were males, with a median age of 65 years, severe or moderate to severe left ventricular dysfunction and in functional class II or I. Ischemic heart disease was the more frequent underlying heart disease followed by dilated cardiomyopathy. The main reason for ICD indication was secondary prevention related to sustained monomorphic ventricular tachycardia or aborted sudden cardiac death. A significant number of prophylactic indications were done, specially in non ischemic heart disease. The proportion of ICD implanted at the electrophysiology laboratory by cardiac electrophysiologist continues increasing. There was an increase in the number of ICD plus cardiac resynchronization therapy, that represent a 23.6% of the implants. The incidence of complications during the implant was very low. Conclusions. The National Registry on ICD, with a participation rate greater than in previous years, provides a representative sample of the ICD implants performed at our country.
引用
收藏
页码:1292 / 1302
页数:11
相关论文
共 9 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]  
BONHORST D, 2003, REV PORT CARDIOL, V25, P353
[3]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[4]   Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy [J].
Kadish, A ;
Dyer, A ;
Daubert, JP ;
Quigg, R ;
Estes, NAM ;
Anderson, KP ;
Calkins, H ;
Hoch, D ;
Goldberger, J ;
Shalaby, A ;
Sanders, WE ;
Schaechter, A ;
Levine, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2151-2158
[5]   National registry of implanted Automatic Defibrillators in 1996 [J].
Madrid, AH ;
Cinca, J ;
Moro, C .
REVISTA ESPANOLA DE CARDIOLOGIA, 1998, 51 (05) :349-355
[6]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[7]   Spanish implantable Cardioverter-Defibrillator Registry.: First official report of the Spanish Society of Cardiology Working Group on Implantable Cardioverter-Defibrillators (2002-2004) [J].
Peinado, R ;
Arenal, A ;
Arribas, F ;
Torrecilla, E ;
Alvarez, M ;
Ormaetxe, JM ;
Pérez-Castellano, N .
REVISTA ESPANOLA DE CARDIOLOGIA, 2005, 58 (12) :1435-1449
[8]  
Proclemer Alessandro, 2005, Ital Heart J, V6, P272
[9]   PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES [J].
SONG, SL ;
BILITCH, M ;
FURMAN, S ;
GROSS, J ;
FRAME, R ;
JOHNSTON, D ;
PARSONNET, V ;
ROTHBART, ST ;
ZIMMERMAN, J ;
KAWANISHI, DT ;
PERRY, GY ;
HASHIMOTO, KK ;
BUCKINGHAM, TA ;
GOLDIN, MD ;
STALLER, BJ ;
DENKER, ST ;
LIPTON, IH ;
CASTLE, LW ;
SHEWCHIK, JM ;
HARTHORNE, JW ;
RUSKIN, JN ;
GARAN, H ;
MCGOVERN, BA ;
GRIFFIN, JC ;
SCHEINMAN, MM ;
LESH, MD ;
DORIAN, P ;
NEWMAN, D ;
DENES, P ;
DAHL, W ;
SAKSENA, S ;
KROL, RB ;
FOGOROS, RN .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (04) :692-708