Effect of cross-flow on the performance of air-cooled heat exchanger fans

被引:35
作者
Stinnes, WH [1 ]
von Backström, TW [1 ]
机构
[1] Univ Stellenbosch, Dept Mech Engn, ZA-7602 Matieland, South Africa
关键词
air-cooled; heat exchangers; cooling plant performance; axial fans; distorted flow; cross-flow; off-axis inflow; fan performance; system effect;
D O I
10.1016/S1359-4311(02)00060-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
In large-scale applications such as arrays of axial fans in air-cooled heat exchanger systems, edge-proximity and wind-induced cross-flow may decrease the flow through some fans by causing the flow to enter them at off-axis angles. In this study, such off-axis inflows were introduced by inserting inlet pipe sections between the plenum chamber of a standard test facility and one of three different scale model test fans of 1542 mm diameter. Fan power consumption turned out to be completely independent of off-axis inflow angle up to 45degrees. Fan total-to-total pressure rise was found to be independent of off-axis inflow angle, and the decrement in fan pressure rise was equal to the dynamic pressure based on the cross-flow velocity component at the fan inlet. Analysis showed that for model fans to represent the cross-flow behaviour of their prototypes, they should have the same ratio of dynamic pressure to pressure rise, and the same dimensionless characteristic slope at their operating points. The performance of a row of fans operating at off-axis inflow conditions representing a cooling system was well predicted by a simple model assuming that the fans farther from the edges induce cross-flows over the fans closer to the edges. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1403 / 1415
页数:13
相关论文
共 16 条
[1]  
*BRIT STAND I, 1980, 848 BRIT STAND I 1
[2]  
Bruneau P. R. P., 1994, THESIS U STELLENBOSC
[3]  
DESOPPER P, 1989, J AM HELICOPTER SOC, V2, P2
[4]   Flow distortions at the fan inlet of forced-draught air-cooled heat exchangers [J].
Duvenhage, K ;
Vermeulen, JA ;
Meyer, CJ ;
Kroger, DG .
APPLIED THERMAL ENGINEERING, 1996, 16 (8-9) :741-752
[5]   The influence of wind on the performance of forced draught air-cooled heat exchangers [J].
Duvenhage, K ;
Kroger, DG .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 62 (2-3) :259-277
[6]  
Kroger D., 1998, AIR COOLED HEAT EXCH
[7]  
LONGLEY JP, 1990, INT GAS TURB AER C E
[8]  
MEYER CJ, 1998, P 2 S AFR C APPL MEC
[9]  
PAZUR W, 1990, INT GAS TURB AER C E
[10]  
PELEAU B, 1989, VERTICA, V13