Effectiveness and safety of sirolimus stent implantation for coronary in-stent restenosis - The TRUE (Tuscany registry of sirolimus for unselected ln-stent restenosis) registry

被引:28
作者
Liistro, Francesco
Fineschi, Massimo
Angioli, Paolo
Sinicropi, Giuseppe
Falsini, Giovanni
Gori, Tommaso
Ducci, Kenneth
Bravi, Achille
Bolognese, Leonardo
机构
[1] San Donato Hosp, Dept Cardiovasc Dis, I-52100 Arezzo, Italy
[2] Le Scotte Hosp, Cardiovasc Dept, Siena, Italy
关键词
D O I
10.1016/j.jacc.2006.03.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to evaluate the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis (ISR) in consecutive unselected patients undergoing coronary intervention in a real-world scenario. BACKGROUND Restenosis after bare metal stenting is characterized by a high rate of re-restenosis once treated with repeated percutaneous coronary intervention. METHODS The study was designed as a prospective two-center registry. We enrolled 244 patients with ISR in a native coronary artery or saphenous vein graft who had clinical indication for repeat intervention. RESULTS Sirolimus stent implantation was successful in all lesions. At 9-month follow-up, death occurred in 4 (1.6%) patients, myocardial infarction in 4 (1.6%), and ischemia-driven target lesion revascularization (TLR) in 12 (4.9%), for a cumulative event-free survival of 227 (93%). Although 9-month follow-up angiography was planned in all patients, only 150 (62%) patients completed it, and restenosis was present in 13 (8.7%) patients. Diabetes and non-ST-segment elevation acute coronary syndrome at presentation were the only independent predictors of freedom from ischemia-driven TLR and major adverse cardiac events. CONCLUSIONS Sirolimus stent implantation for the treatment of ISR is effective and safe. In diabetic patients and in those with acute coronary syndrome, the higher rate of recurrence requires further evaluation.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 27 条
  • [1] Long-term outcome and determinants of event-free survival in patients treated with balloon angioplasty for in-stent restenosis
    Alfonso, F
    Pérez-Vizcayno, MJ
    Hernández, R
    Goicolea, J
    Fernández-Ortíz, A
    Escaned, J
    Bañuelos, C
    Fernández, C
    Macaya, C
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (08) : 1268 - +
  • [2] Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    Colombo, A
    Drzewiecki, J
    Banning, A
    Grube, E
    Hauptmann, K
    Silber, S
    Dudek, D
    Fort, S
    Schiele, F
    Zmudka, K
    Guagliumi, G
    Russell, ME
    [J]. CIRCULATION, 2003, 108 (07) : 788 - 794
  • [3] Elezi S, 1999, CATHETER CARDIO INTE, V48, P151, DOI 10.1002/(SICI)1522-726X(199910)48:2<151::AID-CCD6>3.0.CO
  • [4] 2-C
  • [5] Balloon angioplasty for the treatment of coronary in-stent restenosis: Immediate results and 6-month angiographic recurrent restenosis rate
    Eltchaninoff, H
    Koning, R
    Tron, C
    Gupta, V
    Cribier, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) : 980 - 984
  • [6] Restenosis after coronary placement of various stent types
    Kastrati, A
    Mehilli, J
    Dirschinger, J
    Pache, J
    Ulm, K
    Schühlen, H
    Seyfarth, M
    Schmitt, C
    Blasini, R
    Neumann, FJ
    Schömig, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (01) : 34 - 39
  • [7] Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis -: A randomized controlled trial
    Kastrati, A
    Mehilli, J
    von Beckerath, N
    Dibra, A
    Hausleiter, J
    Pache, J
    Schühlen, H
    Schmitt, C
    Dirschinger, J
    Schömig, A
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (02): : 165 - 171
  • [8] Impact of treatment of coronary artery disease with sirolimus-eluting stents on outcomes of diabetic and nondiabetic patients
    Kuchulakanti, PK
    Torguson, R
    Canos, D
    Rha, SW
    Chu, WW
    Clavijo, L
    Deible, R
    Gevorkian, N
    Suddath, WO
    Satler, LF
    Kent, KA
    Pichard, AD
    Waksman, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (08) : 1100 - 1106
  • [9] Latchem DR, 2000, CATHETER CARDIO INTE, V51, P422, DOI 10.1002/1522-726X(200012)51:4<422::AID-CCD10>3.0.CO
  • [10] 2-A