Balloon angioplasty for the treatment of coronary in-stent restenosis: Immediate results and 6-month angiographic recurrent restenosis rate

被引:99
作者
Eltchaninoff, H [1 ]
Koning, R [1 ]
Tron, C [1 ]
Gupta, V [1 ]
Cribier, A [1 ]
机构
[1] Univ Rouen, Dept Cardiol, Hop Charles Nicolle, F-76000 Rouen, France
关键词
D O I
10.1016/S0735-1097(98)00333-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in stent restenosis. Background. Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. Methods. Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. Results. Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (greater than or equal to 10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16 +/- 7 mm. Balloon diameter of 2.98 +/- 0.37 mm and maximal inflation pressure of 10 +/- 3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in stent restenosis than after stent implantation: 1.19 +/- 0.60 mm VS. 1.75 +/- 0.68 mm (p = 0.0002). At 6-month follow up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization, Angio graphic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p = 0.046. Conclusions. Although balloon angioplasty for in stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:980 / 984
页数:5
相关论文
共 26 条
  • [1] MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE)
    BAIM, DS
    LEVINE, MJ
    LEON, MB
    LEVINE, S
    ELLIS, SG
    SCHATZ, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) : 364 - 366
  • [2] BARRAGAN P, 1995, CATHET CARDIOVASC DI, V32, P123
  • [3] Bauters C, 1998, CIRCULATION, V97, P318
  • [4] DISRUPTION OF A CORONARY STENT DURING ATHERECTOMY FOR RESTENOSIS
    BOWERMAN, RE
    PINKERTON, CA
    KIRK, B
    WALLER, BF
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (04): : 248 - 251
  • [5] GRADING OF ANGINA-PECTORIS
    CAMPEAU, L
    [J]. CIRCULATION, 1976, 54 (03) : 522 - 523
  • [6] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY
    DETRE, K
    HOLUBKOV, R
    KELSEY, S
    COWLEY, M
    KENT, K
    WILLIAMS, D
    MYLER, R
    FAXON, D
    HOLMES, D
    BOURASSA, M
    BLOCK, P
    GOSSELIN, A
    BENTIVOGLIO, L
    LEATHERMAN, L
    DORROS, G
    KING, S
    GALICHIA, J
    ALBASSAM, M
    LEON, M
    ROBERTSON, T
    PASSAMANI, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) : 265 - 270
  • [7] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [8] MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT
    GORDON, PC
    GIBSON, CM
    COHEN, DJ
    CARROZZA, JP
    KUNTZ, RE
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1166 - 1174
  • [9] Hamm C. W., 1997, European Heart Journal, V18, P497
  • [10] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254