Submersible voltammetric probes for in situ real-time trace element measurements in surface water, groundwater and sediment-water interface

被引:36
作者
Tercier-Waeber, ML
Buffle, J
Confalonieri, F
Riccardi, G
Sina, A
Graziottin, F
Fiaccabrino, GC
Koudelka-Hep, M
机构
[1] Univ Geneva, Dept Inorgan & Analyt Chem, CABE, CH-1211 Geneva 4, Switzerland
[2] Idronaut SRL, I-20047 Brugherio, MI, Italy
[3] Univ Neuchatel, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
gel-integrated microsensor; submersible voltammetric probe; in situ profiling system; continuous monitoring; automatic analysis; trace elements; natural aquatic ecosystems;
D O I
10.1088/0957-0233/10/12/312
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A summary of the state of the art in the development of two submersible voltammetric probes performed by us to allow continuous, real-time monitoring of trace elements (Cu(II), Pb(II), Cd(II), Zn(II) and Mn(II), Fe(II)) in natural aquatic ecosystems is given. The first one, called the voltammetric in situ (VIP) profiling system, allowed in situ measurements in surface water and groundwater down to 500 m. Its construction required the development of: (i) a gel-integrated, either single or interconnected, array microsensor, (ii) a submersible probe and (iii) hardware, firmware and software for control of the whole system: i.e. data transmission and acquisition, data processing and maintenance operations. The second system, called the sediment-water interface voltammetric in situ profiling (SIVIP) system, has been developed to allow real-time, high spatial resolution trace elements concentration profile measurements at the sediment-water interface. Its construction required the development of: (i) a gel-integrated microsensor array with 64 individually addressable lines, (ii) a voltammetric probe based on powerful double multiplexing system and single potentiostat allowing simultaneous measurements over the 64 sensor lines, and (iii) hardware, firmware and software for control of the whole system. A general description of both systems as well as examples of laboratory characterization and/or field applications are reported.
引用
收藏
页码:1202 / 1213
页数:12
相关论文
共 24 条
[1]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[2]   Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability [J].
Belmont, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
KoudelkaHep, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :203-214
[3]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[4]  
Buffle J, 1997, CHIMIA, V51, P690
[5]  
Crank J, 1979, MATH DIFFUSION
[6]   POTENTIOSTATIC STUDIES OF ELECTROCHEMICAL NUCLEATION [J].
GUNAWARDENA, GA ;
HILLS, GJ ;
MONTENEGRO, I .
ELECTROCHIMICA ACTA, 1978, 23 (08) :693-697
[7]   Field evaluation of an electrochemical probe for in situ screening of heavy metals in groundwater [J].
Herdan, J ;
Feeney, R ;
Kounaves, SP ;
Flannery, AF ;
Storment, CW ;
Kovacs, GTA ;
Darling, RB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (01) :131-136
[8]  
Luther G. W., 1998, MINERAL MAG A, V62A, P921
[9]  
Madou M., 1997, Fundamentals of Microfabrication
[10]  
OSTERYOUNG J, 1988, ELECTROANALYTICAL CH, V14