Overnight Closed- Loop Insulin Delivery in Young People With Type 1 Diabetes: A Free- Living, Randomized Clinical Trial

被引:145
作者
Hovorka, Roman [1 ,2 ]
Elleri, Daniela [1 ,2 ]
Thabit, Hood [1 ]
Allen, Janet M. [1 ,2 ]
Leelarathna, Lalantha [1 ,3 ]
El-Khairi, Ranna [1 ,2 ]
Kumareswaran, Kavita [1 ,3 ]
Caldwell, Karen [1 ,2 ]
Calhoun, Peter [4 ]
Kollman, Craig [4 ]
Murphy, Helen R. [1 ]
Acerini, Carlo L. [2 ]
Wilinska, Malgorzata E. [1 ,2 ]
Nodale, Marianna [1 ]
Dunger, David B. [1 ,2 ]
机构
[1] Univ Cambridge, Inst Metab Sci, Wellcome Trust Med Res Council, Cambridge, England
[2] Univ Cambridge, Dept Paediat, Cambridge, England
[3] Univ Cambridge, Dept Med, Cambridge CB2 2QQ, England
[4] Jaeb Ctr Hlth Res, Tampa, FL USA
基金
英国医学研究理事会;
关键词
ARTIFICIAL PANCREAS; GLUCOSE CONTROL; PUMP THERAPY; HYPOGLYCEMIA; CHILDREN; ADOLESCENTS; ADULTS;
D O I
10.2337/dc13-2644
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVETo evaluate feasibility, safety, and efficacy of overnight closed-loop insulin delivery in free-living youth with type 1 diabetes.RESEARCH DESIGN AND METHODSOvernight closed loop was evaluated at home by 16 pump-treated adolescents with type 1 diabetes aged 12-18 years. Over a 3-week period, overnight insulin delivery was directed by a closed-loop system, and on another 3-week period sensor-augmented therapy was applied. The order of interventions was random. The primary end point was time when adjusted sensor glucose was between 3.9 and 8.0 mmol/L from 2300 to 0700 h.RESULTSClosed loop was constantly applied over at least 4 h on 269 nights (80%); sensor data were collected over at least 4 h on 282 control nights (84%). Closed loop increased time spent with glucose in target by a median 15% (interquartile range -9 to 43; P < 0.001). Mean overnight glucose was reduced by a mean 14 (SD 58) mg/dL (P < 0.001). Time when glucose was <70 mg/dL was low in both groups, but nights with glucose <63 mg/dL for at least 20 min were less frequent during closed loop (10 vs. 17%; P = 0.01). Despite lower total daily insulin doses by a median 2.3 (interquartile range -4.7 to 9.3) units (P = 0.009), overall 24-h glucose was reduced by a mean 9 (SD 41) mg/dL (P = 0.006) during closed loop.CONCLUSIONSUnsupervised home use of overnight closed loop in adolescents with type 1 diabetes is safe and feasible. Glucose control was improved during the day and night with fewer episodes of nocturnal hypoglycemia.
引用
收藏
页码:1204 / 1211
页数:8
相关论文
共 31 条
[1]  
[Anonymous], NAT PAED DIAB AUD RE
[3]   Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia [J].
Bergenstal, Richard M. ;
Klonoff, David C. ;
Garg, Satish K. ;
Bode, Bruce W. ;
Meredith, Melissa ;
Slover, Robert H. ;
Ahmann, Andrew J. ;
Welsh, John B. ;
Lee, Scott W. ;
Kaufman, Francine R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (03) :224-232
[4]   Fully Integrated Artificial Pancreas in Type 1 Diabetes: Modular Closed-Loop Glucose Control Maintains Near Normoglycemia [J].
Breton, Marc ;
Farret, Anne ;
Bruttomesso, Daniela ;
Anderson, Stacey ;
Magni, Lalo ;
Patek, Stephen ;
Man, Chiara Dalla ;
Place, Jerome ;
Demartini, Susan ;
Del Favero, Simone ;
Toffanin, Chiara ;
Hughes-Karvetski, Colleen ;
Dassau, Eyal ;
Zisser, Howard ;
Doyle, Francis J., III ;
De Nicolao, Giuseppe ;
Avogaro, Angelo ;
Cobelli, Claudio ;
Renard, Eric ;
Kovatchev, Boris .
DIABETES, 2012, 61 (09) :2230-2237
[5]   The Barrier of Hypoglycemia in Diabetes [J].
Cryer, Philip E. .
DIABETES, 2008, 57 (12) :3169-3176
[6]   Closed-Loop Insulin Therapy Improves Glycemic Control in Children Aged &lt;7 Years A randomized controlled trial [J].
Dauber, Andrew ;
Corcia, Liat ;
Safer, Jason ;
Agus, Michael S. D. ;
Einis, Sara ;
Steil, Garry M. .
DIABETES CARE, 2013, 36 (02) :222-227
[7]   Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes [J].
Elleri, Daniela ;
Allen, Janet M. ;
Kumareswaran, Kavita ;
Leelarathna, Lalantha ;
Nodale, Marianna ;
Caldwell, Karen ;
Cheng, Peiyao ;
Kollman, Craig ;
Haidar, Ahmad ;
Murphy, Helen R. ;
Wilinska, Malgorzata E. ;
Acerini, Carlo L. ;
Dunger, David B. ;
Hovorka, Roman .
DIABETES CARE, 2013, 36 (04) :838-844
[8]   Evaluation of a portable ambulatory prototype for automated overnight closed-loop insulin delivery in young people with type 1 diabetes [J].
Elleri, Daniela ;
Allen, Janet M. ;
Biagioni, Martina ;
Kumareswaran, Kavita ;
Leelarathna, Lalantha ;
Caldwell, Karen ;
Nodale, Marianna ;
Wilinska, Malgorzata E. ;
Acerini, Carlo L. ;
Dunger, David B. ;
Hovorka, Roman .
PEDIATRIC DIABETES, 2012, 13 (06) :449-453
[9]  
Geoffrey McGarraugh, 2011, J Diabetes Sci Technol, V5, P99
[10]   Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial [J].
Haidar, Ahmad ;
Legault, Laurent ;
Dallaire, Maryse ;
Alkhateeb, Ammar ;
Coriati, AdSLe ;
Messier, Virginie ;
Cheng, Peiyao ;
Millette, Maude ;
Boulet, Benoit ;
Rabasa-Lhoret, Remi .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2013, 185 (04) :297-305