Development of an optical chemical sensor based on 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol in Nafion for determination of nickel ion

被引:43
作者
Amini, MK [1 ]
Momeni-Isfahani, T [1 ]
Khorasani, JH [1 ]
Pourhossein, M [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
nickel; Br-PADAP; optical sensor; flow system; spectrophotometry;
D O I
10.1016/j.talanta.2003.12.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optical chemical sensor based on immobilization of 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol (Br-PADAP) in Nation membrane is described. The membranes were cast onto glass substrates and were used for the determination of nickel in aqueous solutions by spectrophotometry. The sensor system is highly transparent, mechanically stable and showed no evidence of reagent leaching. The influence of several parameters such as pH, ligand concentration,. and type and concentration of regenerating solution were optimized. The sensor system showed good sensitivity in the range 0.5-20 mug ml(-1) with a detection limit of 0.3 mug ml(-1) Ni(II). The sensor has been incorporated into a home-made flow-through cell for determination of nickel in flowing streams with improved sensitivity, precision and detection limit. The calibration curve in the flow system was linear in the range 0.1-16 mug ml(-1) with a detection limit of 0.07 mug ml(-1). The sensor is easily regenerated by dilute nitric acid solution. The proposed method was successfully applied to the determination of nickel content in vegetable oil and chocolate samples and the results were compared with those obtained using atomic absorption spectrometry. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 40 条
[1]   An optode for the determination of copper, based on 4-decyloxy-2-(2-pyridylazo)-1-naphthol immobilized in poly(vinyl chloride) [J].
Amiet, GR ;
Farrell, JR ;
Iles, PJ ;
Sands, TJ .
AUSTRALIAN JOURNAL OF CHEMISTRY, 2001, 54 (01) :27-30
[2]   IMPREGNATION OF A PH-SENSITIVE DYE INTO SOL-GELS FOR FIBER OPTIC CHEMICAL SENSORS [J].
BADINI, GE ;
GRATTAN, KTV ;
TSEUNG, ACC .
ANALYST, 1995, 120 (04) :1025-1028
[3]  
BERMAN E, 1980, TOXIC METALS THEIR A
[4]   INTELLIGENT SENSOR FOR METAL-IONS BASED ON FLUORESCENCE RESONANCE ENERGY-TRANSFER [J].
BIRCH, DJS ;
HOLMES, AS ;
DARBYSHIRE, M .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (02) :243-247
[5]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[6]   Flow injection extraction spectrophotometric determination of nickel using bis(acetylacetone)ethylenediimine [J].
Chimpalee, N ;
Chimpalee, D ;
Keawpasert, P ;
Burns, DT .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :123-127
[7]   Nafion-PAN optical chemical sensor: optimization by FIA [J].
Coo, LD ;
Belmonte, CJ .
TALANTA, 2002, 58 (06) :1063-1069
[8]   On-line preconcentration system for nickel determination in food samples by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
dos Santos, WNL ;
Lemos, VA .
ANALYTICA CHIMICA ACTA, 2001, 445 (02) :145-151
[9]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177
[10]   Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II) [J].
Gupta, VK ;
Jain, AK ;
Singh, LP ;
Khurana, U .
ANALYTICA CHIMICA ACTA, 1997, 355 (01) :33-41