Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma

被引:44
作者
Anees, W [1 ]
Gannon, PF [1 ]
Huggins, V [1 ]
Pantin, CFA [1 ]
Burge, PS [1 ]
机构
[1] Birmingham Heartlands Hosp, Occupat Lung Dis Unit, Birmingham B9 5SS, W Midlands, England
关键词
Oasys-2; occupational asthma; peak expiratory flow;
D O I
10.1183/09031936.04.00027304
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Serial peak expiratory flow records are recommended in the first-line investigation of suspected occupational asthma. The effects of sequentially reducing the numbers of working weeks, consecutive days at work and readings taken per day on diagnostic sensitivity and specificity were investigated, using good quality peak expiratory flow records from 81 workers with independently confirmed occupational asthma and 60 asthmatics without occupational exposure. Sensitivity was 81.8% for records of 4 weeks' duration and 70% for those of 2 weeks' duration (specificity 93.8 and 82.4%, respectively). The sensitivity fell to 56.7% if there were only 2 consecutive workdays in each work period. Although best at 8 readings-day(-1), sensitivity and specificity were acceptable with four daily readings (82.4 and 87%). The effect of defining a record as being of adequate quality if it was of greater than or equal to2.5 weeks' duration, with greater than or equal to4 readings(.)day(-1) and greater than or equal to3 consecutive workdays in each work period, was tested in records not used in the initial data reduction process. The sensitivity and specificity respectively of adequate records were 78.1 and 91.8 versus 63.6 and 83.3%, for inadequate records. Peak expiratory flow records for the diagnosis of occupational asthma should be interpreted with caution if they do not satisfy the suggested minimum data quantity criteria.
引用
收藏
页码:730 / 734
页数:5
相关论文
共 11 条
[1]   Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma [J].
Burge, PS ;
Pantin, CFA ;
Newton, DT ;
Gannon, PFG ;
Bright, P ;
Belcher, J ;
McCoach, J ;
Baldwin, DR ;
Burge, CBSG .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1999, 56 (11) :758-764
[2]   PEAK FLOW-RATE RECORDS IN THE DIAGNOSIS OF OCCUPATIONAL ASTHMA DUE TO COLOPHONY [J].
BURGE, PS ;
OBRIEN, IM ;
HARRIES, MG .
THORAX, 1979, 34 (03) :308-316
[3]   PEAK FLOW-RATE RECORDS IN THE DIAGNOSIS OF OCCUPATIONAL ASTHMA DUE TO ISOCYANATES [J].
BURGE, PS ;
OBRIEN, IM ;
HARRIES, MG .
THORAX, 1979, 34 (03) :317-323
[4]   SENSITIVITY AND SPECIFICITY OF PC20 AND PEAK EXPIRATORY FLOW-RATE IN CEDAR ASTHMA [J].
COTE, J ;
KENNEDY, S ;
CHANYEUNG, M .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 85 (03) :592-598
[5]   Effect of the number of peak expiratory flow readings per day on the estimation of diurnal variation [J].
Gannon, PFG ;
Newton, DT ;
Pantin, CFA ;
Burge, PS .
THORAX, 1998, 53 (09) :790-792
[6]   Development of OASYS-2: A system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma [J].
Gannon, PFG ;
Newton, DT ;
Belcher, J ;
Pantin, CFA ;
Burge, PS .
THORAX, 1996, 51 (05) :484-489
[7]   Comparison of serial monitoring of peak expiratory flow and FEV1 in the diagnosis of occupational asthma [J].
Leroyer, C ;
Perfetti, L ;
Trudeau, C ;
L'Archevêque, J ;
Chan-Yeung, M ;
Malo, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (03) :827-832
[8]   HOW MANY TIMES PER DAY SHOULD PEAK EXPIRATORY FLOW-RATES BE ASSESSED WHEN INVESTIGATING OCCUPATIONAL ASTHMA [J].
MALO, JL ;
COTE, J ;
CARTIER, A ;
BOULET, LP ;
LARCHEVEQUE, J ;
CHANYEUNG, M .
THORAX, 1993, 48 (12) :1211-1217
[9]   THE ACCURACY OF PORTABLE PEAK FLOW METERS [J].
MILLER, MR ;
DICKINSON, SA ;
HITCHINGS, DJ .
THORAX, 1992, 47 (11) :904-909
[10]  
MOSCATO G, 1995, EUR RESPIR J, V8, P1605