A high-speed capacitive humidity sensor with on-chip thermal reset

被引:166
作者
Kang, US [1 ]
Wise, KD [1 ]
机构
[1] Univ Michigan, Dept Comp Sci & Elect Engn, Ctr Integrated Microsyst, Ann Arbor, MI 48109 USA
关键词
capacitance transducers; humidity transducers; permittivity; polymide films; self-test;
D O I
10.1109/16.830983
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a high-speed capacitive humidity sensor integrated on a polysilicon heater. A response time of 1,0 s and a sensitivity of 30.0 fF/%RH have been obtained. High speed is achieved using multiple polyimide columns having diameters of a few microns and allowing moisture to diffuse into them circumferentially, Using structures that eliminate the air-gap capacitance between the columns, the simulated sensor output drifts by only 1% when the relative dielectric constant in the air region changes from 1 to 10. A polysilicon heater is used to measure relative humidity levels >80%RH. An accuracy of +/-3%RH has been obtained using this method, with measurement errors of +/-0,5 degrees C and +/-2%RH in temperature and relative humidity, respectively, The heater also reduces the recovery time after wetting, enables the sensor to recover from contamination and aging, and allows the sensing film to be reset on demand during self-test protocols.
引用
收藏
页码:702 / 710
页数:9
相关论文
共 37 条
[1]  
ARAI H, SENSORS COMPREHENSIV, V3, pCH20
[2]   HUMIDITY SENSING PROPERTIES AND ELECTRICAL PERMITTIVITY OF NEW PHOTOSENSITIVE POLYIMIDES [J].
BOLTSHAUSER, T ;
CHANDRAN, L ;
BALTES, H ;
BOSE, F ;
STEINER, D .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) :161-164
[3]  
Boltshauser T., 1993, Sensors and Materials, V5, P125
[4]   An experimental verification of saturated salt solution-based humidity fixed points [J].
Carotenuto, A ;
DellIsola, M .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1996, 17 (06) :1423-1439
[5]  
Crank J, 1979, MATH DIFFUSION
[6]   POLYMER-BASED CAPACITIVE HUMIDITY SENSOR - CHARACTERISTICS AND EXPERIMENTAL RESULTS [J].
DELAPIERRE, G ;
GRANGE, H ;
CHAMBAZ, B ;
DESTANNES, L .
SENSORS AND ACTUATORS, 1983, 4 (01) :97-104
[7]  
DELPIERRE G, 1983, SENSOR ACTUATOR, V4, P97
[8]   MOISTURE DIFFUSION IN POLYIMIDE FILMS IN INTEGRATED-CIRCUITS [J].
DENTON, DD ;
DAY, DR ;
PRIORE, DF ;
SENTURIA, SD ;
ANOLICK, ES ;
SCHEIDER, D .
JOURNAL OF ELECTRONIC MATERIALS, 1985, 14 (02) :119-136
[9]  
DENTON DD, 1990, P IEEE 33 MIDW S CIR, P854
[10]   An improved electric hygrometer [J].
Dunmore, FW .