Real-time US elastography in the differentiation of suspicious microcalcifications on mammography
被引:59
作者:
Cho, Nariya
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
Seoul Natl Univ Hosp, Clin Res Inst, Seoul 100744, South Korea
Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South KoreaSeoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
Cho, Nariya
[1
,2
,3
]
Moon, Woo Kyung
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
Seoul Natl Univ Hosp, Clin Res Inst, Seoul 100744, South Korea
Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South KoreaSeoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
Moon, Woo Kyung
[1
,2
,3
]
论文数: 引用数:
h-index:
机构:
Park, Jeong-Seon
[4
]
机构:
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
[2] Seoul Natl Univ Hosp, Clin Res Inst, Seoul 100744, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[4] Hanyang Univ, Dept Radiol, Coll Med, Hanyang Univ Hosp, Seoul 133791, South Korea
The purpose of this study was to retrospectively evaluate the use of US elastography in the differentiation of mammographically detected suspicious microcalcifications, using histology as the reference standard. Between May 2006 and April 2007, real-time US elasticity images were obtained in 77 patients (age range, 24-67 years; mean, 46 years) with 77 mammographically detected areas of microcalcifications (42 benign and 35 malignant lesions) prior to needle biopsy. Two experienced radiologists reviewed cine clips of elasticity and B-mode images and assigned an elasticity score of 1 to 3 in consensus, based on the degree of strain in the hypoechoic lesion without information of mammography and histology. For the elasticity score, the mean +/- standard deviation was 1.5 +/- 0.7 for benign and 2.7 +/- 0.7 for malignant lesions (P < 0.001). When a cutoff point between elasticity scores of 1 and 2 was used, US elastography showed 97% (34/35) sensitivity, 62% (26/42) specificity, 68% (34/50) PPV, and 96% (26/27) NPV with an Az value of 0.852 (0.753-0.923, 95% confidence interval) in the differentiation of benign and malignant microcalcifications. Our results suggest that US elastography has the potential to differentiate benign and malignant lesions associated with microcalcifications detected at screening mammography.
机构:
Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Booi, Rebecca C.
;
Carson, Paul L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Carson, Paul L.
;
论文数: 引用数:
h-index:
机构:
O'Donnell, Matthew
;
论文数: 引用数:
h-index:
机构:
Roubidoux, Marilyn A.
;
Hall, Anne L.
论文数: 0引用数: 0
h-index: 0
机构:
Gen Elect Hlth Care, Milwaukee, WI USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
机构:
Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Booi, Rebecca C.
;
Carson, Paul L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
Carson, Paul L.
;
论文数: 引用数:
h-index:
机构:
O'Donnell, Matthew
;
论文数: 引用数:
h-index:
机构:
Roubidoux, Marilyn A.
;
Hall, Anne L.
论文数: 0引用数: 0
h-index: 0
机构:
Gen Elect Hlth Care, Milwaukee, WI USAUniv Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA