In vivo real-time freehand palpation imaging

被引:344
作者
Hall, TJ [1 ]
Zhu, YN [1 ]
Spalding, CS [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66103 USA
关键词
ultrasound; tissue characterization; elasticity; palpation; elastography;
D O I
10.1016/S0301-5629(02)00733-0
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Previous experience with laboratory fixtures and off-line processing of elasticity data showed that problems occurring in data acquisition often resulted in poor elasticity image quality. A system for real-time estimation and display of tissue elastic properties using a clinical ultrasonic imaging system has been developed. A brief description of that system and the initial clinical tests of that system are reported. Experience with real-time freehand elasticity imaging shows that images with high contrast-to-noise ratios are consistently obtained. Images of breast lesions were acquired with freehand palpation using standard linear-array ultrasound (US) transducers. Results in volunteer patients show that high-quality elasticity images are easily obtained from in vivo breast studies. The key element to successful scanning is real-time visual feedback of B-mode and strain images that guide the patient positioning and compression direction. Results show that individual images of axial strain in tissues can be quite misleading, and that a "movie loop" of side-by-side B-mode and strain images provides significantly more information. Our preliminary data suggest that the strain image sequences for various breast pathologies are unique. For example, strain images of fibroadenomas lose contrast with increasing precompression, but those of invasive ductal carcinoma have high negative contrast (dark relative to "normal" tissue) for a wide range of precompression. In addition, a comparison of the lesion area measured in B-mode vs. strain images, for a representative image from the sequence, appears to be a sensitive criterion for separating invasive ductal carcinoma from cyst and fibroadenoma. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:427 / 435
页数:9
相关论文
共 11 条
[1]   Testing the limitations of 2-D companding for strain imaging using phantoms [J].
Chaturvedi, P ;
Insana, MF ;
Hall, TJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :1022-1031
[2]   2-D companding for noise reduction in strain imaging [J].
Chaturvedi, P ;
Insana, MF ;
Hall, TJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :179-191
[3]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[4]   Phantom materials for elastography [J].
Hall, TJ ;
Bilgen, M ;
Insana, MF ;
Krouskop, TA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1355-1365
[5]  
Insana MF, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P1435, DOI 10.1109/ULTSYM.1997.661847
[6]   A least-squares strain estimator for elastography [J].
Kallel, F ;
Ophir, J .
ULTRASONIC IMAGING, 1997, 19 (03) :195-208
[7]   Elastic moduli of breast and prostate tissues under compression [J].
Krouskop, TA ;
Wheeler, TM ;
Kallel, F ;
Garra, BS ;
Hall, T .
ULTRASONIC IMAGING, 1998, 20 (04) :260-274
[8]   Adaptive strain estimation using retrospective processing [J].
Lubinski, MA ;
Emelianov, SY ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (01) :97-107
[9]  
Tavassoli FA, 1999, PATHOLOGY BREAST
[10]   A modified block matching method for real-time freehand strain imaging [J].
Zhu, YN ;
Hall, TJ .
ULTRASONIC IMAGING, 2002, 24 (03) :161-176